The IV tubing must be long enough to reach from the top of the lamp across to my left
forearm ...prob. eight feet.
<br/>
It should be a
<b>10 drop per ml set</b>
: I believe its the
<b> Baxter Continu-Flo Solution Set with a Male Luer Lock Adapter</b>
.
<br/>
<b>106 inches long (2.7 meter</b>
). It has an in-line filter. It says Interlink System. It has a spike at one end and
the luer lock at the other.
<br/>
(The secondary medication sets have the right connectors but are TOO SHORT! These are
intended for use with a main IV line to be plugged into
<br/>
a side port. There is, however, a separate 43 inch extension set that may enable you to
use the secondary med. set, if it is the only alternative.)
</p>
<p>
1) use a 20 gauge intracath in your L forearm (the insyte auto...) Also should have the
IV prep kit with a tourniquet and prep and op site.
<br/>
to start it ... shave off all the hair, wash it thoroughly, clease with alcohol or
betadine.
<br/>
Apply tournequet. Use diaper pail to catch blood and put chucks on the floor ... blood
all over the place.
<br/>
How do you stop the blood once you are in? Put on the little connector set (6 inch long
tubing called a T connector). This is really essential.
<br/>
It is the answer to the question ... how do you disconnect the IV tubing with solution
from the intracath without getting blood all over the floor???
<br/>
It supplies two answers: 1) it has a latex membrane over it that you spike with a little
connector that you place at the end of the IV tubing and also
<br/>
2) in the course of the 6 inch T-connector tubing it has a slider cut-off that may be used
to interrupt flow. It is essential.
</p>
<p>
2)Irrigate it either with the ready filled 5 ml NS irrigation syringes OR use a 5 ml
syringe and fill it with a
<br/>
NS from a 10 ml bottle of NS.
</p>
<p>
3) How do you grab the intracath? Use a hemostat and clamp it to the narrowest portion of
the plastic sleeve (the portion that is abt 3mm dia);
<br/>
Now place the handle of the hemostat (the clamp handle) btwn your knees! That will
stabilize it ... that is much better than
<br/>
your mouth. Take off your glasses first.
</p>
<p>
4) Hang the
<b>250 ml IV bag (either D5W or NS ... </b>
the 500 ml bag is too much fluid
<b>) </b>
from the lamp shade to get a pressure head.
<br/>
Spike it with an IV connector set and FLUSH the line before you connect it to the
intracath!!! Flush it into the plastic wastebasket.
<br/>
To connect the line to the intracath use a needless, blunt connector (abt 1 inch long) ...
luer lock to blunt connector that
<br/>
you push thru the latex membrance on the 6 inch T-connector set. Get the 250 ml bags
from IV room at Fremont (they don't seem to have 250 ml bags at Hayward).
</p>
<p>
<br/>
5) Having irrigated the intracath, connect the IV tubing and run it at 1 drop per second
(use a macro drip = 10 drops per ml)
<br/>
So 1 drop per second = 60 drops per minute = 6 ml per min = 240 ml in 40 mins.
</p>