MOLECULE, Single localization Webinar Science Nov 11, 2015
<p class="MsoNormal" >MOLECULE, Single localization Webinar Science Nov 11, 2015
this is a Webinar at 9AM Pacific sponsored by Science Mag.
It originates in Europe.
moderator is Sean Sanders in Wash DC...
<b>Markus Sauer </b>begins (<b>Wurzburg</b>)
shows Chinin and Fluorescein...
shows multicolor images
shows Ernst Abbe 1873 and Rayleigh (RAY -lee)...
1/2 wavelength of light... limit of resolution.
<b>it is ON the GRAVESTONE of Abbe</b>!!! d= lambda over 2 etc.
Nobel in Chem 2014 Betzig, Stefan Hell, et al.
separate fluor
2500 squares (50 by 50) in one square micron.
where each is 50 nano on a side.
now switch teh tiny squares off and on over time async...
and now can see them even tho way below lambda over 2.
dSTORM eg
shows phalloidin a toxin from death cap that binds to F actin.
shows video....
after 30,000 frames...
get incred. resolution...
shows microtubules filaments...
reconstruct MTs.
dSTORM of mitochondria... eg inner MT membrane
and can see folding of inner membrane and christae!!
studying plasm membs using click chem and dSTORM.
Glycan imaging on cell membrane... 5M glycans on plasma memb.
SYNAPSES: Andreska in Frontiers in Cell Neurosci 2014...
see presynap and post sites...
BDNF is located in single vesicles within glutamatergic presynapes of cultured HC neurons.
but how reliable is this technique... false + and false - ... reliability?
use nuclear pore complex eg to correlate dSTORM and scanning EM = SEM.
and overlay them.
=> only 0.1% of all NPCs = nuclear proe complexs are not seen in
dSTORM images and
99% of NPCs are imaged.
yes... do correlateive microscopy and SEM...
eg SNC = synaptonemal complex... (homologous chromosomes)
see 3d model of SNC... chromosomes together during meiosis.
in his group... lots of fly neuron imaging.
crash pilot (in German) if elim this protein then fly cannot fly (drosoph)
see diffs in vesicle recruitment... ST synaptic plasticity...
active zones in brain slices
how is function encoded at the molecular level?
in tauma, stress, stroke, etc.
see Bassoon and Homer molecules in R and L hemisphere...
he has a massive group!!! German govt and German res fnd.
*
2nd Speaker... is <b>Christian Soeller</b> from
Univ of Exeter in UK.
biomed physics... pron solar. (German origin)
will talk abt SMLM single molecule localization microscopy...
shows the Gartner hypecycle
tech trigger... then inflated expectations and then disillusionment then slope of enlightment
the platau of productivity...
The HYPE cycle...
hard to overhype SMLM... it's great!
one of the most robust! eg of the dSTORM variety.
shows cardiac myocyte in a tissue slice...
focus here on antibody stained smaple (usual stuff)
nice to start with other techniques and get high contrast image.... gives hope of doing dSTORM.
eg glycosylated proteins...
how to get robust dSTORM working...
make molcules switch (on and off)
shows fluor when transitions occur ... to get to photo blinking.
need some primary thiols and helps to reduce free O2.
(Markus was orig a chemist... most of us are not)
shows fiber probe to check local O2 in specimen in liquid.
thiols are labile... Ellman's reagent.
make sure buffers are working...
we use open slide with a well in it (cavity in the middle of it)
trying to shift colors... (this is directd to beginners with this)
shows test slides (to get going with this)
Gattaquant super-resolution slides (buy these to trouble shoot your techniques)
RyR clusters... seen with dSTORM
heart muscle cells...contraciton in heart.
how well do the contract. can see receptors.
can see make up of clusters.... SMLM => example is dSTORM.
can go down to 25 nm !!! res.
can label RyR clusters label them
eg from Soeller and Baddeley in JMCC 2013.
how many receptors are present in these clusters... shows model with 30 nm pixel.
see relationship btwn RyR and alpha-actinin.
as in Hou in JMCC 2014...
sCMOS camera for super-res...
pixel properties unfortun change from pixel to pixel... some have poor readout.
he shows the variance when imaging test beads.
so can get bias in localization... must correct for this...
last point: emCCD vs sCMOS compare quantum efficiency...
CMOS effic. is perhaps 10% better. but some apps for emCCDs.
conclusions:
progress in camera tech will incr ease of use, speed and reduce cost of SMLM
Orla Hanrahan in Belfast, ireland
she works for ANDOR an Oxford Instr company
her title is fast and sensitive solutions for super res Microscopy
PALM/ STORM is a single molecule deteciton appraoch... so must be v sensitive...
cuz v low intensity signal...
and localalizaiton width is proport. to 1 over SNR.
speed want to acquite multipel iamges as fast as possible for summation.
detectors...
2 key params: 10 quantum efficiency (how effic. at converting
photons into electrons in the detectors)
used to be CCD was camera of choice but moving to CMOS.
convert photon sto photoelectrons...
2nd para is noise floor: want a low noise floor to high SNR.
can get 4T sCMOS 4 transistors per pixel vs
5T (which ha sless efficienty cuz less light gets thru)
shows peak effic around 550 to 600 nm.
noise... made up of read noise, floor noise and shot noise. and dark noise.
v fast readout...
if high QE quant effic.. that's good.
sCMOS = scientific CMOS is uqinue in simult offering
extreme low noise... down to 0.9 electrons.
rapid frame rates 100 fps
wide dynamic range...
shows diff btwn CCD and CMOS
CCD must transfer translated electrons row by row during readout...
but in CMOS each pixel is like a separ sensor (that's good but => variance)
shows blow up view...
microlens... amplifier transistor and reset xsistor
photodiode/ potential well and silicon substrate...
sCMOS fast acquis speeds... v low read noise
large field is 2048 by 2048 to get 53 fps...
but at 512 by 512 can get 406 fps.
Diskovery... a new platform from ANDOR (her company)
can do confocal , TIRF, SMSM
Borealis their instrument...
can look from 400 to 800 nm...
shows zoom illumination
look at partic ROI.
* on to audience questions in Webinar audience
Q1: localize center of mass of photon point spread function...
size of antibody eg is 10 nm each ...
so size of label is
Nyquist theorem... to get res at 20 nm... must attach at every10 nm by Nyquist.
Q2: original STORM vs dSTORM...
original had to have 2 difft dyes on same molecules... so that one would stim theother
but needed in molec proximity...
but with dSTORM ... just buy it... one fluor... simplified it enormously.
Q3: how do photofluors actually flash?
in nl imaging... all are one..
with STORM keep most OFF... so that they are not excitable
but then stochas visible... switching on and off.
Q4: speed of camera in regard to phototoxicity
(ie laser or LED can bleach the sample... destroy it...
really want short exposure times)
so, yes... speed is important...
short exposure is good.