CMMC 2.0 — SC.L3-03.13.15E Separate Subnets to Isolate System Components and Functions
source: false
type: canonical-control-reference
standard: CMMC 2.0
profile: "Level 3 additive SP 800-172r3 project baseline"
regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"
document_version: "SP 800-172r3 project baseline"
level: 3
practice_id: "SC.L3-03.13.15E"
source_requirement_id: "03.13.15E"
family_id: "03.13"
domain_id: "SC"
family: "System and Communications Protection"
title: "Separate Subnets to Isolate System Components and Functions"
status: active
baseline_mode: additive
level_2_prerequisite: true
level_2_controls_duplicated: false
scoring_method: "one-point-per-additional-requirement project assumption"
point_value: 1
assessment_reevaluation: conditional
assessment_poam_eligible: "not-defined-for-project-baseline"
deferred_documentation: "re-evaluation-only"
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-172r3 verified transcription"
- "NIST SP 800-172Ar3 verified transcription"
- "32 CFR Part 170 CMMC Program Final Rule"
canonical_source_card: "NIST SP 800-172r3 03.13.15E"
source_controls:
- "NIST SP 800-53r5 SC-07(29)"
source_assessment_procedures:
- "NIST SP 800-53Ar5 SC-07(29)"
SC.L3-03.13.15E Separate Subnets to Isolate System Components and Functions
Project-defined additive Level 3 profile
This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.
CMMC Level 3 — Additive Profile
- Level 2 prerequisite: All Level 2 requirements remain prerequisites and are maintained only in CMMC 2.0 Level 2. They are not duplicated in this folder.
- Additional requirement source: NIST SP 800-172r3 03.13.15E.
- Point value: 1 point under this project profile, following the current CMMC Level 3 one-point-per-additional-requirement model.
- In-assessment correction / re-evaluation: Conditionally permitted for a NOT MET Level 3 requirement during the assessment and for 10 business days following the active assessment period, when additional evidence demonstrates MET, does not materially affect previously assessed requirements, and is provided before the Assessment Findings Report is delivered.
- Assessment POA&M: Not assigned at the individual-card level. The current regulatory exclusion list applies to the legacy 24-requirement CMMC v2.13 selection and cannot be accurately projected onto the complete SP 800-172r3 catalog without an approved successor mapping.
- Deferred documentation: No separate deferred-documentation finding is assumed. Draft, unofficial, or unapproved documentation is not acceptable evidence; corrections are handled through re-evaluation.
Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.
NIST SP 800-172r3 — Enhanced Security Requirement
Implement [Selection (one): physically; logically] separate subnetworks to isolate the following critical system components and functions: [Assignment: organization-defined critical system components and functions].
Discussion
Separating critical system components and functions from other noncritical system components and functions through separate subnetworks may be necessary to reduce susceptibility to a catastrophic or debilitating breach or compromise that results in system failure. For example, physically separating the command-and-control function from the in-flight entertainment function through separate subnetworks in a commercial aircraft provides an increased level of assurance in the trustworthiness of critical system functions. This requirement enhances SP 800-171 requirement 03.13.01.
Protection Strategy
PRA
Adversary Effects
Preclude (Preempt), Impede (Exert), Limit (Reduce)
References
Source Controls — NIST SP 800-53r5
NIST SP 800-172Ar3 — Assessment Procedure
Assessment Objective
Determine if:
A.03.13.15E.ODP[01]: one of the following PARAMETER VALUES is selected: {physically; logically}.
A.03.13.15E.ODP[02]: critical system components and functions to be isolated are defined.
A.03.13.15E: subnetworks are separated <A.03.13.15E.ODP[01]: SELECTED PARAMETER VALUE> to isolate <A.03.13.15E.ODP[02]: critical system components and functions>.
Assessment Methods and Objects
Examine
[SELECT FROM: System and communications protection policy; procedures addressing boundary protection; system design documentation; system hardware and software; system architecture; system configuration settings and associated documentation; criticality analysis; system audit records; system security plan; other relevant documents or records].
Interview
[SELECT FROM: System/network administrators; organizational personnel with information security responsibilities; system developer; organizational personnel with boundary protection responsibilities].
Test
[SELECT FROM: Mechanisms separating critical system components and functions].
References
Source Assessment Procedures — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-07(29)