Open in TheBrain

CMMC 2.0 — SC.L3-03.13.15E Separate Subnets to Isolate System Components and Functions


source: false

type: canonical-control-reference

standard: CMMC 2.0

profile: "Level 3 additive SP 800-172r3 project baseline"

regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"

document_version: "SP 800-172r3 project baseline"

level: 3

practice_id: "SC.L3-03.13.15E"

source_requirement_id: "03.13.15E"

family_id: "03.13"

domain_id: "SC"

family: "System and Communications Protection"

title: "Separate Subnets to Isolate System Components and Functions"

status: active

baseline_mode: additive

level_2_prerequisite: true

level_2_controls_duplicated: false

scoring_method: "one-point-per-additional-requirement project assumption"

point_value: 1

assessment_reevaluation: conditional

assessment_poam_eligible: "not-defined-for-project-baseline"

deferred_documentation: "re-evaluation-only"

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-172r3 verified transcription"

- "NIST SP 800-172Ar3 verified transcription"

- "32 CFR Part 170 CMMC Program Final Rule"

canonical_source_card: "NIST SP 800-172r3 03.13.15E"

source_controls:

- "NIST SP 800-53r5 SC-07(29)"

source_assessment_procedures:

- "NIST SP 800-53Ar5 SC-07(29)"


SC.L3-03.13.15E Separate Subnets to Isolate System Components and Functions

Project-defined additive Level 3 profile

This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.

CMMC Level 3 — Additive Profile

Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.

NIST SP 800-172r3 — Enhanced Security Requirement

Implement [Selection (one): physically; logically] separate subnetworks to isolate the following critical system components and functions: [Assignment: organization-defined critical system components and functions].

Discussion

Separating critical system components and functions from other noncritical system components and functions through separate subnetworks may be necessary to reduce susceptibility to a catastrophic or debilitating breach or compromise that results in system failure. For example, physically separating the command-and-control function from the in-flight entertainment function through separate subnetworks in a commercial aircraft provides an increased level of assurance in the trustworthiness of critical system functions. This requirement enhances SP 800-171 requirement 03.13.01.

Protection Strategy

PRA

Adversary Effects

Preclude (Preempt), Impede (Exert), Limit (Reduce)

References

Source Controls — NIST SP 800-53r5

NIST SP 800-172Ar3 — Assessment Procedure

Assessment Objective

Determine if:

A.03.13.15E.ODP[01]: one of the following PARAMETER VALUES is selected: {physically; logically}.

A.03.13.15E.ODP[02]: critical system components and functions to be isolated are defined.

A.03.13.15E: subnetworks are separated <A.03.13.15E.ODP[01]: SELECTED PARAMETER VALUE> to isolate <A.03.13.15E.ODP[02]: critical system components and functions>.

Assessment Methods and Objects

Examine

[SELECT FROM: System and communications protection policy; procedures addressing boundary protection; system design documentation; system hardware and software; system architecture; system configuration settings and associated documentation; criticality analysis; system audit records; system security plan; other relevant documents or records].

Interview

[SELECT FROM: System/network administrators; organizational personnel with information security responsibilities; system developer; organizational personnel with boundary protection responsibilities].

Test

[SELECT FROM: Mechanisms separating critical system components and functions].

References

Source Assessment Procedures — NIST SP 800-53Ar5