NIST SP 800-53r5 — SC-45(01) Synchronization with Authoritative Time Source
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "SC-45(01)"
family_id: "SC"
family: "System and Communications Protection"
title: "Synchronization with Authoritative Time Source"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: false
SC-45(01) Synchronization with Authoritative Time Source
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
- (a) Compare the internal system clocks [Assignment: organization-defined frequency] with [Assignment: organization-defined authoritative time source]; and
- (b) Synchronize the internal system clocks to the authoritative time source when the time difference is greater than [Assignment: organization-defined time period].
Discussion
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
Related Controls
- None specified.
Supporting Publications
- None specified.
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
SC-45(01)_ODP[01]— the frequency at which to compare the internal system clocks with the authoritative time source is defined; -
SC-45(01)_ODP[02]— the authoritative time source to which internal system clocks are to be compared is defined; -
SC-45(01)_ODP[03]— the time period to compare the internal system clocks with the authoritative time source is defined; -
SC-45(01)(a)— the internal system clocks are compared <SC-45(01)_ODP[01]frequency> with <SC-45(01)_ODP[02]authoritative time source>; -
SC-45(01)(b)— the internal system clocks are synchronized with the authoritative time source when the time difference is greater than <SC-45(01)_ODP[03]time period>.
Potential Assessment Methods and Objects
Examine
Select from:
- System and communications protection policy.
- procedures addressing time synchronization.
- system design documentation.
- system configuration settings and associated documentation.
- system audit records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- System/network administrators.
- organizational personnel with information security responsibilities.
- organizational personnel installing, configuring, and/or maintaining the system.
Test
Select from:
- Mechanisms supporting and/or implementing system time synchronization.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-45(01)
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Not included |
Reference
- NIST SP 800-53B baseline tables