NERC CIP — CIP-015-2 R1 Internal Network Security Monitoring
source: false
type: "canonical-control-reference"
standard: "NERC Critical Infrastructure Protection"
document_version: "CIP-015-2"
criterion_id: "CIP-015-2 R1"
family_id: "CIP-015-2"
family: "Cyber Security – Internal Network Security Monitoring"
title: "Internal Network Security Monitoring"
status: "approved-future-enforcement"
assessment_criterion: true
normative_text_included: true
updated: "2026-09-13"
source_pdf: "Resources/CMMC Brain 2.1/Sources/NERC CIP/CIP-015-2.pdf"
source_pages: [4, 5, 8, 9]
requirement_pages: [4, 5]
us_effective_date: "10/01/2029"
mapping_status: "not-transferred-from-2024-SCF-set"
CIP-015-2 R1 Internal Network Security Monitoring
Version and enforcement
U.S. status checked 2026-09-13: Subject to Future Enforcement. Standard effective date: 10/01/2029. The implementation plan has phased compliance milestones through 2031; this is not a single all-systems deadline. Jurisdiction-specific applicability and transitional obligations must be checked against the implementation plan.
Requirement
Each Responsible Entity shall implement one or more documented process(es) for internal network security monitoring of network activity between Cyber Systems that are part of any Applicable Systems identified in CIP-015-2 Table R1 – Internal Network Security Monitoring. The documented process(es) shall collectively include each of the applicable requirement parts in CIP-015-2 Table R1 – Internal Network Security Monitoring: [Violation Risk Factor: Medium] [Time Horizon: Same Day Operations and Operations Assessment]
Note: 1.) Network activity to or from non-CIP devices, 2.) network activity to or from low impact BES Cyber Systems (BCS), and 3.) the network activity between discrete Electronic Security Perimeters; are all out of scope.
Assessment Measure
Evidence must include each of the applicable documented process(es) that collectively include each of the applicable requirement parts in CIP-015-2 Table R1 – Internal Network Security Monitoring and additional evidence to demonstrate implementation as described in the Measures column of the table.
Requirement Parts
Part 1.1
Applicable Systems
High Impact BCS and their associated:
-
1.Electronic Access Control and Monitoring Systems (EACMS);
-
2.Physical Access Control Systems (PACS); and
-
3.Protected Cyber Asset (PCA)
Medium Impact BCS with External Routable Connectivity (ERC) and their associated:
-
1.EACMS;
-
2.PACS; and
-
3.PCA
Shared Cyber Infrastructure (SCI) supporting an Applicable System in this Part.
Requirement
Implement, using a risk-based rationale, network data feed(s) to monitor network activity; including connections, devices, and network communications.
Measures
Examples of evidence may include, but are not limited to, documentation detailing network data feed(s) that includes a documented risk-based rationale that describes how network data feed(s) were selected for data collection.
Part 1.2
Applicable Systems
High Impact BCS and their associated:
-
1.EACMS;
-
2.PACS; and
-
3.PCA
Medium Impact BCS with ERC and their associated:
-
1.EACMS;
-
2.PACS; and
-
3.PCA
SCI supporting an Applicable System in this Part.
Requirement
Implement one or more method(s) to detect anomalous network activity using the network data feed(s) from Part 1.1.
Measures
Examples of evidence may include, but are not limited to:
- Documentation of anomalous network detection events;
- Documentation of configuration settings of internal network security monitoring systems;
- Documentation of network communication baseline used to detect anomalous network activity; or
- Documentation of other methods used to detect anomalous network activity.
Part 1.3
Applicable Systems
High Impact BCS and their associated:
-
1.EACMS;
-
2.PACS; and
-
3.PCA
Medium Impact BCS with ERC and their associated:
-
1.EACMS;
-
2.PACS; and
-
3.PCA
SCI supporting an Applicable System in this Part.
Requirement
Implement one or more method(s) to evaluate anomalous network activity detected in Part 1.2 to determine further action(s).
Measures
Examples of evidence may include, but are not limited to:
- Documentation of method(s) used to evaluate anomalous activity;
- Documentation of actions taken in response to detected anomalies; or
- Documentation of escalation process(es) that could include CIP-008 Cyber Security Incident response plan(s).
Violation Severity Levels
Lower
N/A
Moderate
For network activity between Cyber Systems that are part of any EACMS or PACS associated with a high impact BCS or medium impact BCS with ERC, the Responsible Entity did not implement, using a risk-based rationale, network data feed(s) to monitor network activity; including connections, devices, and network communications (1.1). OR For network activity between Cyber Systems that are part of any EACMS or PACS associated with a high impact BCS or medium impact BCS with ERC, the Responsible Entity did not implement one or more method(s) to detect anomalous network activity using the network data feed(s) from Part 1.1 (1.2). OR For network activity between Cyber Systems that are part of any EACMS or PACS associated with a high impact BCS or medium impact BCS with ERC, the Responsible Entity did not implement one or more method(s) to evaluate anomalous network activity detected in Part 1.2. to determine further action(s) (1.3).
High
For network activity between Cyber Systems that are part of any high impact BCS or medium impact BCS with ERC and their associated PCA, the Responsible Entity did not implement, using a risk-based rationale, network data feed(s) to monitor network activity; including connections, devices, and network communications (1.1). OR For network activity between Cyber Systems that are part of any high impact BCS or medium impact BCS with ERC and their associated PCA, the Responsible Entity did not implement one or more method(s) to detect anomalous network activity using the network data feed(s) from Part 1.1 (1.2). OR For network activity between Cyber Systems that are part of any high impact BCS or medium impact BCS with ERC and their associated PCA, the Responsible Entity did not implement one or more method(s) to evaluate anomalous network activity detected in Part 1.2. to determine further action(s) (1.3).
Severe
The Responsible Entity did not include any of the applicable requirement parts for detecting and evaluating anomalous network activity.
Applicability and Evidence Retention
CIP-015-2 applicability, exemptions, compliance monitoring, and evidence retention.
Referenced Publications
- CIP-015-2 official standard; PDF page(s) 4, 5, 8, 9. NERC original PDF.
- NERC standard status and dates (checked 2026-09-13).
- CIP-015-2 implementation plan. NERC original implementation plan.
Notes
- Assessment reference scope: the complete numbered requirement, associated parts and measures are kept together. Source wording is transcribed; line wrapping and presentation are normalized. The official PDF controls if a discrepancy is found.
- Table columns are presented as labeled subsections for each part so applicability, requirements, and measures remain associated.
- Publicly available does not mean public domain. This is an internal reference, not an NERC publication or endorsement.
- Legacy SCF relationships refer to the 2024 versioned mapping set; no cross-version equivalence is asserted.