ISO IEC 27002 2022 — 7.13 Equipment maintenance
source: false
type: canonical-control-reference
standard: "ISO/IEC 27002"
document_version: "2022"
element_id: "7.13"
family_id: "7"
family: "Physical Controls"
title: "Equipment maintenance"
status: active
assessment_criterion: true
reference_basis: "user-supplied licensed ISO canonical publication"
normative_text_included: true
source_location: "PDF pages 89–90; printed pages 79–80"
updated: 2026-09-11
scf_mappings: ["MNT-01", "MNT-02", "MNT-03"]
authoritative_sources:
- "ISO/IEC 27002:2022 canonical PDF"
text_kind: guidance
source_text_verified: true
7.13 Equipment maintenance
Control Attributes
| Attribute | Value |
|---|---|
| Control type | #Preventive |
| Information security properties | #Confidentiality #Integrity #Availability |
| Cybersecurity concepts | #Protect |
| Operational capabilities | #Physical_security #Asset_management |
| Security domains | #Protection #Resilience |
Control
Equipment should be maintained correctly to ensure availability, integrity and confidentiality of information.
Purpose
To prevent loss, damage, theft or compromise of information and other associated assets and interruption to the organization’s operations caused by lack of maintenance.
Guidance
The following guidelines for equipment maintenance should be considered:
- a) maintaining equipment in accordance with the supplier’s recommended service frequency and specifications;
- b) implementing and monitoring of a maintenance programme by the organization;
- c) only authorized maintenance personnel carrying out repairs and maintenance on equipment;
- d) keeping records of all suspected or actual faults, and of all preventive and corrective maintenance;
- e) implementing appropriate controls when equipment is scheduled for maintenance, taking into account whether this maintenance is performed by personnel on site or external to the organization; subjecting the maintenance personnel to a suitable confidentiality agreement;
- f) supervising maintenance personnel when carrying out maintenance on site;
- g) authorizing and controlling access for remote maintenance;
- h) applying security measures for assets off-premises (see 7.9) if equipment containing information is taken off premises for maintenance;
- i) complying with all maintenance requirements imposed by insurance;
- j) before putting equipment back into operation after maintenance, inspecting it to ensure that the equipment has not been tampered with and is functioning properly;
- k) applying measures for secure disposal or re-use of equipment (see 7.14) if it is determined that equipment is to be disposed of.
Other Information
Equipment includes technical components of information processing facilities, uninterruptible power supply (UPS) and batteries, power generators, power alternators and converters, physical intrusion detection systems and alarms, smoke detectors, fire extinguishers, air conditioning and lifts.
SCF Relationships
Mappings below are from the SCF STRM for ISO/IEC 27002; the source element and relationship are retained.
| Source element | SCF control | Relationship | Strength | Mapping PDF page |
|---|---|---|---|---|
7.13 | MNT-01 (unresolved reference: References/Secure Controls Framework 2026.2/MNT Maintenance/MNT-01 Maintenance Operations.md) | Subset Of | 10 | 10 |
7.13 | MNT-02 (unresolved reference: References/Secure Controls Framework 2026.2/MNT Maintenance/MNT-02 Controlled Maintenance.md) | Intersects With | 5 | 10 |
7.13 | MNT-03 (unresolved reference: References/Secure Controls Framework 2026.2/MNT Maintenance/MNT-03 Timely Maintenance.md) | Intersects With | 5 | 10 |
Notes
- Subordinate paragraphs and lists remain on this clause or control card.
- Assessment reference: This publication supplies recommendations and guidance; applicability depends on the assessment scope.
References
- ISO/IEC 27002:2022 — canonical source, PDF pages 89–90; printed pages 79–80.
- SCF STRM mapping source.