NIST SP 800-53r5 — SC-45 System Time Synchronization
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "SC-45"
family_id: "SC"
family: "System and Communications Protection"
title: "System Time Synchronization"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: false
related_controls:
- "AC-03"
- "AU-08"
- "IA-02"
- "IA-08"
SC-45 System Time Synchronization
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Synchronize system clocks within and between systems and system components.
Discussion
Time synchronization of system clocks is essential for the correct execution of many system services, including identification and authentication processes that involve certificates and time-of-day restrictions as part of access control. Denial of service or failure to deny expired credentials may result without properly synchronized clocks within and between systems and system components. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. The granularity of time measurements refers to the degree of synchronization between system clocks and reference clocks, such as clocks synchronizing within hundreds of milliseconds or tens of milliseconds. Organizations may define different time granularities for system components. Time service can be critical to other security capabilities—such as access control and identification and authentication—depending on the nature of the mechanisms used to support the capabilities.
Related Controls
- AC-03
- AU-08
- IA-02
- IA-08
Supporting Publications
- IETF 59051
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
SC-45— system clocks are synchronized within and between systems and system components.
Potential Assessment Methods and Objects
Examine
Select from:
- System and communications protection policy.
- procedures addressing time synchronization.
- system design documentation.
- system configuration settings and associated documentation.
- system audit records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- System/network administrators.
- organizational personnel with information security responsibilities.
- organizational personnel installing, configuring, and/or maintaining the system.
Test
Select from:
- Mechanisms supporting and/or implementing system time synchronization.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-45
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Not included |
Reference
- NIST SP 800-53B baseline tables
Referenced Publications
1 Internet Engineering Task Force (IETF), Request for Comments: 5905, Network Time Protocol Version 4: Protocol and Algorithms Specification, June 2010. https://tools.ietf.org/pdf/rfc5905.pdf