NIST SP 800-53r5 — AU-05(04) Shutdown on Failure
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "AU-05(04)"
family_id: "AU"
family: "Audit and Accountability"
title: "Shutdown on Failure"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: false
related_controls:
- "AU-15"
AU-05(04) Shutdown on Failure
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Invoke a [Selection: full system shutdown; partial system shutdown; degraded operational mode with limited mission or business functionality available] in the event of [Assignment: organization-defined audit logging failures], unless an alternate audit logging capability exists.
Discussion
Organizations determine the types of audit logging failures that can trigger automatic system shutdowns or degraded operations. Because of the importance of ensuring mission and business continuity, organizations may determine that the nature of the audit logging failure is not so severe that it warrants a complete shutdown of the system supporting the core organizational mission and business functions. In those instances, partial system shutdowns or operating in a degraded mode with reduced capability may be viable alternatives.
Related Controls
- AU-15
Supporting Publications
- None specified.
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
AU-05(04)_ODP[01]— one or more of the following PARAMETER VALUES is/are selected: {full system shutdown; partial system shutdown; degraded operational mode with limited mission or business functionality available}; -
AU-05(04)_ODP[02]— audit logging failures that trigger a change in operational mode are defined; -
AU-05(04)— <AU-05(04)_ODP[01]SELECTED PARAMETER VALUE(S)> is/are invoked in the event of <AU-05(04)_ODP[02]audit logging failures> , unless an alternate audit logging capability exists.
Potential Assessment Methods and Objects
Examine
Select from:
- Audit and accountability policy.
- procedures addressing response to audit processing failures.
- system design documentation.
- system security plan.
- privacy plan.
- system configuration settings and associated documentation.
- system audit records.
- other relevant documents or records.
Interview
Select from:
- Organizational personnel with audit and accountability responsibilities.
- organizational personnel with information security and privacy responsibilities.
- system/network administrators.
- system developers.
Test
Select from:
- System capability invoking system shutdown or degraded operational mode in the event of an audit processing failure.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 AU-05(04)
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Not included |
Reference
- NIST SP 800-53B baseline tables