Secure Controls Framework 2026.2 — NET-01.1 Zero Trust Architecture (ZTA)
source: false
type: canonical-control-reference
standard: Secure Controls Framework 2026.2
control_id: "NET-01.1"
domain_id: "NET"
domain: "Network Security"
title: "Zero Trust Architecture (ZTA)"
status: active
validation_cadence: "Annual"
relative_control_weighting: "8"
pptdf_applicability: "Technology"
nist_csf_function: "Protect"
updated: 2026-09-10
authoritative_sources:
- "SCF 2026.2 workbook"
- "SCF Overview & Practitioner Guidebook, version 2026.2"
source_sheet: "SCF 2026.2"
source_row: 963
source_workbook_sha256: "9e0a4df4993726c95e636f04b3028d8b5edeba2bda45d16ed6722b13540e6835"
source_fidelity_audit: "2026-09-13"
NET-01.1 Zero Trust Architecture (ZTA)
Canonical SCF 2026.2 reference
Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.
Source and mapping limits
This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.
SCF 2026.2 — Control
Mechanisms exist to treat all users and devices as potential threats and prevent access to data and resources until the users can be properly authenticated and their access authorized.
Domain Principle
Network Security (NET): Architect and implement defense-in-depth network protections that segment, restrict and monitor access to Technology Assets, Applications, Services and Data (TAASD).
Organizations architect and operate security, compliance and resilience controls that protect the Confidentiality, Integrity, Availability and Safety (CIAS) of network infrastructure through segmentation, traffic control, secure connectivity and situational awareness of network activity.
Control Question
Does the organization treat all users and devices as potential threats and prevent access to data and resources until the users can be properly authenticated and their access authorized?
Operational Metadata
| Field | Value |
|---|---|
| Conformity validation cadence | Annual |
| Relative control weighting | 8 |
| PPTDF applicability | Technology |
| NIST CSF function grouping | Protect |
Possible Solutions & Considerations
Micro-Small Business
- Not specified.
Small Business
- Not specified.
Medium Business
- Zero Trust Architecture (ZTA) planning and roadmap
Large Business
- ZTA implementation
- Identity-centric access controls
- Microsegmentation
Enterprise
- Enterprise ZTA platform (e.g., Zscaler, Palo Alto Prisma Access)
- Identity-based access
- Microsegmentation
- Continuous validation
Assessment Objectives
NET-01.1_A01
all users are treated as potential threats and prevent access to data and resources until the user can be properly authenticated and their access authorized.
PPTDF applicability:
- Technology
Origin(s):
-
SCF Created
Assessment rigor:
- 1
NET-01.1_A02
all devices are treated as potential threats and prevent access to data and resources until the device can be properly authenticated and its access authorized.
PPTDF applicability:
- Technology
Origin(s):
-
SCF Created
Assessment rigor:
- 1
Evidence Requests
-
E-NET-05— Zero Trust Architecture (ZTA) (Network Security): Documented evidence of controls that would enable the organization to claim conformity with Zero Trust (ZT) principles.
Compensating Controls
Risk if Primary Control Is Not Implemented
Without Zero Trust Architecture (ZTA), residual security, compliance, or resilience risk may accumulate, potentially leading to control failures or non-compliance.
Possible Compensating Control 1
NET-03 — Boundary Protection
Mechanisms exist to monitor and control communications at the external network boundary and at key internal boundaries within the network.
Justification:
Boundary Protection (NET-03) provides network-level access restriction that compensates for the absence of Zero Trust Architecture (ZTA) (NET-01.1) by limiting attacker reach and lateral movement opportunities across the environment. Given the technology-focused nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Possible Compensating Control 2
MON-01 — Continuous Monitoring
Mechanisms exist to facilitate the implementation of enterprise-wide monitoring controls.
Justification:
Continuous Monitoring (MON-01) provides detective monitoring capability that compensates for the absence of Zero Trust Architecture (ZTA) (NET-01.1) by identifying unauthorized, anomalous, or non-compliant activity that the primary control would have prevented. Given the technology-focused nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Applicability and Profile Membership
- SCRM Focus TIER 1 STRATEGIC: Included
- SCRM Focus TIER 2 OPERATIONAL: Included
- SCRM Focus TIER 3 TACTICAL: Included
- SCR-CMM Level 0 Not Performed:
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
- SCR-CMM Level 1 Performed Informally:
Network Security (NET) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include:
- Policies, standards & procedures associated with NET domain capabilities provide limited coverage due to the depth and breadth of the existing documentation.
- Network security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices.
- Administrative processes are used to configure boundary devices (e.g., firewalls, routers, etc.) to deny network traffic by default and allow network traffic by exception (e.g., deny all, permit by exception).
- SCR-CMM Level 2 Planned & Tracked:
SCR-CMM Level 2 criteria definitions are not available for this control:
- A reasonable person would conclude a well-defined and standardized process is required.
- At this level of maturity, the “requirements-driven” nature of performing the control is focused on a localized and/or regionalized implementation, not uniform and consistent across the organization.
- Requirements are narrowly scoped for applicability and are primarily derived from compliance obligations (e.g., laws, regulations and contracts).
- SCR-CMM Level 3 Well Defined:
Network Security (NET) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with NET domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.
- Standardized Operating Procedures (SOP) associated with NET domain capabilities are well-documented and kept current by process owners.
- A network security management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities.
- Technology is leveraged to enhance the efficiency and accuracy of network security operations (e.g., network management solution, log aggregator, etc.).
- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with NET domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).
- Secure Baseline Configurations (SBC) enforce the principles of least privileges and least functionality for boundary protection technologies.
- An implemented and operational capability exists to treat all users and devices as potential threats and prevent access to data and resources until the users can be properly authenticated and their access authorized.
- SCR-CMM Level 4 Quantitatively Controlled:
Utilize SCR-CMM Level 3 criteria definitions:
- There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control.
- While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define.
- SCR-CMM Level 5 Continuously Improving:
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:
- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.
- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.
- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
Framework Mappings
- AICPA Trust Services Criteria (2017; revised Points of Focus 2022):
CC6.1-POF5 - Center for Internet Security (CIS) Critical Security Controls (CSC) version 8.1:
13.5 - Center for Internet Security (CIS) Critical Security Controls (CSC) version 8.1 - IG2:
13.5 - Center for Internet Security (CIS) Critical Security Controls (CSC) version 8.1 - IG3:
13.5 - Cloud Security Alliance (CSA) Internet of Things Security Controls Framework v2:
SNT-02 - Cyber Resilience Capability Maturity Model (CR - CMM) (2026):
CR4.1.5 - International Electrotechnical Commission 62443 - 4 - 2 Ed. 1.0 b:2019 - Security for industrial automation and control systems - Part 4 - 2: Technical security requirements for IACS components:
NDR 1.13 - Motion Picture Association (MPA) Content Security Best Practices Common Guidelines v5.3.1:
TS-6.0,TS-6.1,TS-6.2 - NIST SP 800 - 207 - Zero Trust Architecture:
NIST Tenet 3,NIST Tenet 5,NIST Tenet 6 - US - Department of War (DoW) - Zero Trust Execution Roadmap v1.1:
5.1.1,6.2.3 - US - Department of War (DoW) - Zero Trust Reference Architecture v2:
3.0 - Australia - Information Security Manual (ISM) (March 2026):
ISM-0665 - India - SEBI Cybersecurity and Cyber Resilience Framework (2024):
PR.AA.S4 - Japan - Information System Security Management and Assessment Program (ISMAP):
9.1.1.16 - New Zealand - Information Security Manual (ISM) v3.9:
2.3.26.C.01,2.3.26.C.02,16.1.25.C.01,16.5.12.C.02
Minimum Security Requirements
- No MCR or DSR designation is specified in the source workbook.
Risk and Threat Mappings
Risks
-
R-AC-1 -
R-AC-2 -
R-AC-3 -
R-AC-4 -
R-AM-1 -
R-AM-2 -
R-BC-1 -
R-BC-2 -
R-BC-3 -
R-BC-4 -
R-BC-5 -
R-EX-1 -
R-EX-2 -
R-EX-3 -
R-EX-4 -
R-EX-5 -
R-EX-6 -
R-EX-7 -
R-GV-1 -
R-GV-2 -
R-GV-3 -
R-GV-4 -
R-GV-5 -
R-GV-6 -
R-GV-7 -
R-GV-8 -
R-IR-1 -
R-IR-2 -
R-IR-3 -
R-IR-4 -
R-SA-1 -
R-SC-1 -
R-SC-2 -
R-SC-3 -
R-SC-4 -
R-SC-5 -
R-SC-6
Threats
-
NT-7 -
MT-1 -
MT-2 -
MT-7 -
MT-8 -
MT-9 -
MT-10 -
MT-11 -
MT-12 -
MT-13 -
MT-14 -
MT-15 -
MT-24 -
MT-25 -
MT-27 -
MT-28
Source References
- Secure Controls Framework 2026.2 workbook
- SCF Overview & Practitioner Guidebook, version 2026.2