CMMC 2.0 — AC.L3-03.01.12E Physical or Logical Separation of CUI Flows
source: false
type: canonical-control-reference
standard: CMMC 2.0
profile: "Level 3 additive SP 800-172r3 project baseline"
regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"
document_version: "SP 800-172r3 project baseline"
level: 3
practice_id: "AC.L3-03.01.12E"
source_requirement_id: "03.01.12E"
family_id: "03.01"
domain_id: "AC"
family: "Access Control"
title: "Physical or Logical Separation of CUI Flows"
status: active
baseline_mode: additive
level_2_prerequisite: true
level_2_controls_duplicated: false
scoring_method: "one-point-per-additional-requirement project assumption"
point_value: 1
assessment_reevaluation: conditional
assessment_poam_eligible: "not-defined-for-project-baseline"
deferred_documentation: "re-evaluation-only"
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-172r3 verified transcription"
- "NIST SP 800-172Ar3 verified transcription"
- "32 CFR Part 170 CMMC Program Final Rule"
canonical_source_card: "NIST SP 800-172r3 03.01.12E"
source_controls:
- "NIST SP 800-53r5 AC-04(21)"
source_assessment_procedures:
- "NIST SP 800-53Ar5 AC-04(21)"
AC.L3-03.01.12E Physical or Logical Separation of CUI Flows
Project-defined additive Level 3 profile
This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.
CMMC Level 3 — Additive Profile
- Level 2 prerequisite: All Level 2 requirements remain prerequisites and are maintained only in CMMC 2.0 Level 2. They are not duplicated in this folder.
- Additional requirement source: NIST SP 800-172r3 03.01.12E.
- Point value: 1 point under this project profile, following the current CMMC Level 3 one-point-per-additional-requirement model.
- In-assessment correction / re-evaluation: Conditionally permitted for a NOT MET Level 3 requirement during the assessment and for 10 business days following the active assessment period, when additional evidence demonstrates MET, does not materially affect previously assessed requirements, and is provided before the Assessment Findings Report is delivered.
- Assessment POA&M: Not assigned at the individual-card level. The current regulatory exclusion list applies to the legacy 24-requirement CMMC v2.13 selection and cannot be accurately projected onto the complete SP 800-172r3 catalog without an approved successor mapping.
- Deferred documentation: No separate deferred-documentation finding is assumed. Draft, unofficial, or unapproved documentation is not acceptable evidence; corrections are handled through re-evaluation.
Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.
NIST SP 800-172r3 — Enhanced Security Requirement
Separate CUI flows logically or physically using [Assignment: organization-defined mechanisms and/or techniques].
Discussion
Enforcing the separation of information flows associated with defined types of data can enhance protection by ensuring that CUI is not commingled while in transit and by enabling flow control by transmission paths that are not otherwise achievable. This requirement enhances SP 800-171 requirement 03.01.03.
Protection Strategy
PRA
Adversary Effects
Preclude (Preempt), Impede (Exert)
References
Source Controls — NIST SP 800-53r5
NIST SP 800-172Ar3 — Assessment Procedure
Assessment Objective
Determine if:
A.03.01.12E.ODP[01]: mechanisms and/or techniques to separate CUI flows are defined.
A.03.01.12E: CUI flows are logically or physically separated using <A.03.01.12E.ODP[01] mechanisms and/or techniques>.
Assessment Methods and Objects
Examine
[SELECT FROM: Information flow enforcement policy; information flow control policies; procedures addressing information flow enforcement; system design documentation; system configuration settings and associated documentation; list of required separation of information flows by information types; list of mechanisms and/or techniques used to logically or physically separate information flows; system audit records; system security plan; other relevant documents or records].
Interview
[SELECT FROM: Organizational personnel with information flow enforcement responsibilities; system/network administrators; organizational personnel with information security responsibilities; system developers].
Test
[SELECT FROM: Mechanisms implementing information flow enforcement functions].
References
Source Assessment Procedure: AC-04(21)