Open in TheBrain

NIST SP 800-172r3 — 03.13.14E Detonation Chambers


source: false

type: canonical-control-reference

standard: NIST SP 800-172r3

assessment_standard: NIST SP 800-172Ar3

control_id: "03.13.14E"

family_id: "03.13"

family: "System and Communications Protection"

title: "Detonation Chambers"

status: active

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-172r3 verified transcription"

- "NIST SP 800-172Ar3 verified transcription"

source_controls:

- "NIST SP 800-53r5 SC-44"

source_assessment_procedures:

- "NIST SP 800-53Ar5 SC-44"


03.13.14E Detonation Chambers

Canonical combined reference

Requirement text comes from NIST SP 800-172r3. Assessment procedures come from NIST SP 800-172Ar3. Assessment identifiers retain their NIST-defined bracket and dot syntax.

NIST SP 800-172r3 — Enhanced Security Requirement

Employ a detonation chamber capability within [Assignment: organization-defined system, system component, or location].

Discussion

Detonation chambers (also known as dynamic execution environments) allow organizations to open email attachments, execute untrusted or suspicious applications, and execute URL requests in the safety of an isolated environment or a virtualized sandbox. Protected and isolated execution environments provide a means of determining whether the associated attachments or applications contain malicious code. While related to the concept of deception nets, the employment of detonation chambers is not intended to maintain a long-term environment in which adversaries can operate and their actions can be observed. Rather, detonation chambers are intended to quickly identify malicious code and either reduce the likelihood that the code is propagated to user environments of operation or prevent such propagation completely. This requirement does not enhance a specific requirement in SP 800-171 but can be used to strengthen the protection of CUI associated with critical programs or high value assets.

Protection Strategy

PRA, DLO

Adversary Effects

Preclude (Preempt, Negate), Impede (Contain, Exert), Expose (Detect, Reveal)

References

Source Controls — NIST SP 800-53r5

NIST SP 800-172Ar3 — Assessment Procedure

Assessment Objective

Determine if:

A.03.13.14E.ODP[01]: the system, system component, or location in which a detonation chamber capability is to be employed is defined.

A.03.13.14E: a detonation chamber capability is employed within the <A.03.13.14E.ODP[01]: system, system component, or location>.

Assessment Methods and Objects

Examine

[SELECT FROM: System and communications protection policy; procedures addressing detonation chambers; system configuration settings and associated documentation; system audit records; system design documentation; system security plan; other relevant documents or records].

Interview

[SELECT FROM: system/network administrators; personnel with information security responsibilities; personnel installing, configuring, and/or maintaining the system].

Test

[SELECT FROM: Mechanisms supporting and/or implementing the detonation chamber capability].

References

Source Assessment Procedures — NIST SP 800-53Ar5