HIPAA Security Rule 2013 — § 164.312(c)(2) Implementation specification- Mechanism to authenticate electronic protected health information (Addressable)
source: false
type: canonical-control-reference
standard: "HIPAA Security Rule"
document_version: "45 CFR Part 164 Subpart C; 2025 annual edition"
criterion_id: "§ 164.312(c)(2)"
family_id: "164.312"
family: "Section 164.312"
title: "Implementation specification: Mechanism to authenticate electronic protected health information (Addressable)"
status: active
assessment_criterion: true
reference_basis: "public regulation, official NIST crosswalk and guidance, and public-source STRM"
normative_text_included: true
updated: 2026-09-13
scf_mappings:
- "CFG-08"
- "CFG-08.1"
- "MON-01.7"
- "MON-01.15"
- "MON-16"
authoritative_sources:
- "45 CFR Part 164, Subpart C — government XML (2025 edition)"
- "NIST HIPAA Security Rule to SP 800-53 Rev. 5.1.1 Crosswalk (2024)"
- "SCF STRM HIPAA Security Rule 2013"
source_text_verified: true
source_xml_sha256: "786d8abda6e14b71d37c3596b3196b1aa956af54487e006a2116ebe153d16b7c"
§ 164.312(c)(2) Implementation specification: Mechanism to authenticate electronic protected health information (Addressable)
Public-source assessment reference
This card organizes publicly available requirement text and SCF mappings. Verify currency and applicability against the authoritative publication.
Criterion Text
-
164.312(c)(2)Implementation specification: Mechanism to authenticate electronic protected health information (Addressable). Implement electronic mechanisms to corroborate that electronic protected health information has not been altered or destroyed in an unauthorized manner.
Governing provision text
A covered entity or business associate must, in accordance with § 164.306:
Regulatory Context
This provision is part of the HIPAA Security Rule's technical safeguards. Its card designation is Addressable. Under § 164.306(d)(3), assess whether an addressable specification is reasonable and appropriate. If it is, implement it. If it is not, document why it is not reasonable and appropriate, and implement an equivalent alternative measure if that alternative is reasonable and appropriate. Confirm entity status, ePHI scope, and any provision-specific conditions against the current eCFR.
HHS OCR Audit Protocol
The HHS OCR Audit Protocol includes the following Security Rule audit row(s) represented by this card:
-
164.312(c)(2)— Mechanism to authenticate electronic protected health information
- Card designation: Addressable
- Operational evidence focus: Review technical policies, system configurations, access records, and system-generated evidence demonstrating that the mechanism operates as designed.
Audit-protocol scope
The evidence focus above is an operational synthesis, not a verbatim replacement for OCR's provision-specific inquiry. The 2018 protocol assesses selected requirements and may vary by entity type; use the official protocol row for the complete inquiry and document request.
Open the official HHS OCR Audit Protocol
NIST Cross-References
Official NIST SP 800-53 Rev. 5.1.1 relationships
The following relationships are transcribed from NIST's 2024 OLIR crosswalk. They are informative relationships, not statements of equivalence or automatic HIPAA compliance.
- NIST SP 800-53r5 SC-08 — Transmission Confidentiality and Integrity
- NIST SP 800-53r5 SI-07 — Software, Firmware, and Information Integrity
Derived NIST SP 800-171 Rev. 3 references
These references are derived only where a NIST SP 800-171r3 requirement names the same SP 800-53r5 control as a source control. NIST has not designated these as a direct HIPAA-to-SP 800-171 crosswalk; they support navigation and analysis, not equivalence or compliance inheritance.
- NIST SP 800-171r3 03.13.08 — Transmission and Storage Confidentiality (via SP 800-53r5
SC-08)
SCF Relationships
- SCF CFG-08 — Sensitive - Regulated Data Access Enforcement (Intersects With; strength 5)
- SCF CFG-08.1 — Sensitive - Regulated Data Actions (Intersects With; strength 5)
- SCF MON-01.7 — File Integrity Monitoring (FIM) (Intersects With; strength 5)
- SCF MON-01.15 — Privileged User Oversight (Intersects With; strength 5)
- SCF MON-16 — Anomalous Behavior (Intersects With; strength 5)
Notes
- Text audit (2026-09-13): Criterion wording and governing paragraphs were checked against the retained 2025 annual CFR edition. Original paragraph identifiers are preserved; the edition is not silently presented as a live eCFR snapshot. The previously cited HTML download contained an access-denied page.
- Assessment-criteria scope: This card represents one leaf-level HIPAA Security Rule obligation used as an operational assessment criterion. Structural headings and non-substantive parent provisions are not maintained as separate cards.
- Source disclaimer: This operational reference is not legal advice and does not determine applicability or compliance. Confirm the current authoritative law, implementing rules, regulator guidance, and counsel's interpretation.
References
- 45 CFR Part 164 — government PDF (2025 edition)
- 45 CFR Part 164, Subpart C — government XML (2025 edition)
- NIST HIPAA Security Rule to SP 800-53 Rev. 5.1.1 Crosswalk (2024)
- NIST SP 800-66 Rev. 2
- SCF STRM HIPAA Security Rule 2013
- Official source