Secure Controls Framework 2026.2 — SEA-01.5 Security-Aware Design
source: false
type: canonical-control-reference
standard: Secure Controls Framework 2026.2
control_id: "SEA-01.5"
domain_id: "SEA"
domain: "Secure Engineering & Architecture"
title: "Security-Aware Design"
status: active
validation_cadence: "Annual"
relative_control_weighting: "7"
pptdf_applicability: "Process"
nist_csf_function: "Protect"
updated: 2026-09-10
authoritative_sources:
- "SCF 2026.2 workbook"
- "SCF Overview & Practitioner Guidebook, version 2026.2"
source_sheet: "SCF 2026.2"
source_row: 1299
source_workbook_sha256: "9e0a4df4993726c95e636f04b3028d8b5edeba2bda45d16ed6722b13540e6835"
source_fidelity_audit: "2026-09-13"
SEA-01.5 Security-Aware Design
Canonical SCF 2026.2 reference
Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.
Source and mapping limits
This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.
SCF 2026.2 — Control
Mechanisms exist to formally incorporate the organization's secure architecture principles into engineering, product and model design requirements to ensure security, compliance and resilience are built in by default and by design.
Domain Principle
Secure Engineering & Architecture (SEA): Apply industry-recognized secure engineering and architecture principles to deliver secure, compliant and resilient systems, applications and services.
Organizations align cybersecurity engineering and architecture decisions with the organization’s technology strategy and industry-recognized practices, including secure-by-design, threat modeling, resilience engineering and defensible architecture decisions.
Control Question
Does the organization formally incorporate its secure architecture principles into engineering, product and model design requirements to ensure security, compliance and resilience are built in by default and by design?
Operational Metadata
| Field | Value |
|---|---|
| Conformity validation cadence | Annual |
| Relative control weighting | 7 |
| PPTDF applicability | Process |
| NIST CSF function grouping | Protect |
Possible Solutions & Considerations
Micro-Small Business
- Security design checklist for new systems or applications
- OWASP Top 10 design guidance
Small Business
- OWASP secure design principles
- Security requirements in development projects
Medium Business
- Security-by-design requirements integrated into SDLC
- Threat modeling for new systems
- OWASP Threat Dragon or similar
Large Business
- Enterprise secure-by-design program
- Threat modeling requirements in SDLC
- Security architecture approval for new projects
- Privacy and security design reviews
Enterprise
- Enterprise security-aware design program
- Automated threat modeling integration in SDLC
- Security and privacy design reviews for all new systems
- Board-approved security-by-design policy
Assessment Objectives
SEA-01.5_A01
secure architecture principles are incorporated into engineering, product and model design requirements to ensure security, compliance and resilience are built in by default and by design.
PPTDF applicability:
- Process
Origin(s):
-
SCF Created
Assessment rigor:
- 1
Evidence Requests
- No evidence request is assigned in the source workbook.
Compensating Controls
Risk if Primary Control Is Not Implemented
Without Security-Aware Design, security design weaknesses may be built into systems, increasing long-term vulnerability and the cost of remediation.
Possible Compensating Control 1
SEA-01 — Secure Engineering Principles
Mechanisms exist to facilitate the implementation of industry-recognized security, compliance and resilience practices in the specification, design, development, implementation and modification of Technology Assets, Applications and/or Services (TAAS).
Justification:
Secure Engineering Principles (SEA-01) provides secure engineering and architectural guidance that compensates for the absence of Security-Aware Design (SEA-01.5) by embedding security requirements into design processes as an alternative control mechanism. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Possible Compensating Control 2
PRM-04 — Security, Compliance & Resilience In Project Management
Mechanisms exist to assess security, compliance and resilience controls as part of Technology Assets, Applications and/or Services (TAAS) project development to determine whether controls are implemented correctly, operating as intended and producing the desired outcome with respect to meeting requirements.
Justification:
Security, Compliance & Resilience In Project Management (PRM-04) provides resilience and recovery capability that compensates for the absence of Security-Aware Design (SEA-01.5) by ensuring the organization can restore operations when the primary control is absent. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Applicability and Profile Membership
- SCRM Focus TIER 1 STRATEGIC: Included
- SCRM Focus TIER 2 OPERATIONAL: Included
- SCR-CMM Level 0 Not Performed:
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
- SCR-CMM Level 1 Performed Informally:
SCR-CMM Level 1 criteria definitions are not available for this control:
- A reasonable person would conclude this control requires a structured process.
- At this level of maturity, the "ad hoc" nature of performing a capability informally would indicate the intent of the control is not met due to a lack of consistency and formality.
- SCR-CMM Level 2 Planned & Tracked:
Secure Engineering & Architecture (SEA) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with SEA domain capabilities are formally documented and centrally-managed by the entity.
- Standardized Operating Procedures (SOP) associated with SEA domain capabilities are documented and maintained by process owners.
- IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with SEA domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD).
- Secure engineering and architecture-related controls are primarily administrative and preventative in nature (e.g., policies, standards, procedures & guidelines).
- Secure engineering and architecture management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel.
- SCR-CMM Level 3 Well Defined:
Secure Engineering & Architecture (SEA) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with SEA domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.
- Standardized Operating Procedures (SOP) associated with SEA domain capabilities are well-documented and kept current by process owners.
- A cybersecurity engineering / architecture team, or similar function, is appropriately staffed and supported to implement and maintain RSK domain capabilities.
- Technology is leveraged to enhance the efficiency and accuracy of secure engineering management operations (e.g., project management solution, etc.).
- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with SEA domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).
- Secure Baseline Configurations (SBC) enforce the secure engineering principles on all applicable Technology Assets, Applications and/or Services (TAAS).
- An implemented and operational capability exists to formally incorporate the organization's secure architecture principles into engineering, product and model design requirements to ensure security, compliance and resilience are built in by default and by design.
- SCR-CMM Level 4 Quantitatively Controlled:
Utilize SCR-CMM Level 3 criteria definitions:
- There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control.
- While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define.
- SCR-CMM Level 5 Continuously Improving:
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:
- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.
- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.
- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
- SCF Community Derived: 26Q2-010
Framework Mappings
- NIST SP 800 - 172 R3 - Enhanced Security Requirements for Protecting Controlled Unclassified Information:
03.15.01E - NIST SP 800 - 172A R3 - Assessing Enhanced Security Requirements for Controlled Unclassified Information:
DS-A.03.15.01E.a.01,DS-A.03.15.01E.a.02 - New Zealand - Information Security Manual (ISM) v3.9:
2.3.28.C.01
Minimum Security Requirements
- No MCR or DSR designation is specified in the source workbook.
Risk and Threat Mappings
Risks
-
R-AC-1 -
R-AC-2 -
R-AC-3 -
R-AC-4 -
R-AM-1 -
R-AM-2 -
R-BC-1 -
R-BC-2 -
R-BC-3 -
R-BC-4 -
R-BC-5 -
R-EX-1 -
R-EX-2 -
R-EX-3 -
R-EX-4 -
R-EX-5 -
R-EX-6 -
R-EX-7 -
R-GV-1 -
R-GV-2 -
R-GV-3 -
R-GV-4 -
R-GV-5 -
R-GV-6 -
R-GV-7 -
R-GV-8 -
R-IR-1 -
R-IR-2 -
R-IR-3 -
R-IR-4 -
R-SA-1 -
R-SA-2 -
R-SC-1 -
R-SC-2 -
R-SC-3 -
R-SC-4 -
R-SC-5 -
R-SC-6
Threats
-
NT-7 -
MT-1 -
MT-2 -
MT-7 -
MT-8 -
MT-9 -
MT-11 -
MT-12 -
MT-13 -
MT-14 -
MT-15 -
MT-24 -
MT-25 -
MT-27 -
MT-28
SCF 2026.2 Errata
- new control - SCF community
Source References
- Secure Controls Framework 2026.2 workbook
- SCF Overview & Practitioner Guidebook, version 2026.2