NIST SP 800-53r5 — SC-48 Sensor Relocation
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "SC-48"
family_id: "SC"
family: "System and Communications Protection"
title: "Sensor Relocation"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: false
related_controls:
- "AU-02"
- "SC-07"
- "SI-04"
SC-48 Sensor Relocation
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Relocate [Assignment: organization-defined sensors and monitoring capabilities] to [Assignment: organization-defined locations] under the following conditions or circumstances: [Assignment: organization-defined conditions or circumstances].
Discussion
Adversaries may take various paths and use different approaches as they move laterally through an organization (including its systems) to reach their target or as they attempt to exfiltrate information from the organization. The organization often only has a limited set of monitoring and detection capabilities, and they may be focused on the critical or likely infiltration or exfiltration paths. By using communications paths that the organization typically does not monitor, the adversary can increase its chances of achieving its desired goals. By relocating its sensors or monitoring capabilities to new locations, the organization can impede the adversary’s ability to achieve its goals. The relocation of the sensors or monitoring capabilities might be done based on threat information that the organization has acquired or randomly to confuse the adversary and make its lateral transition through the system or organization more challenging.
Related Controls
Supporting Publications
- SP 800-160-21
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
SC-48_ODP[01]— sensors and monitoring capabilities to be relocated are defined; -
SC-48_ODP[02]— locations to where sensors and monitoring capabilities are to be relocated are defined; -
SC-48_ODP[03]— conditions or circumstances for relocating sensors and monitoring capabilities are defined; -
SC-48— <SC-48_ODP[01]sensors and monitoring capabilities> are relocated to <SC-48_ODP[02]locations> under <SC-48_ODP[03]conditions or circumstances>.
Potential Assessment Methods and Objects
Examine
Select from:
- System and communications protection policy.
- procedures addressing sensor and monitoring capability relocation.
- list of sensors/monitoring capabilities to be relocated.
- change control records.
- configuration management records.
- system design documentation.
- system configuration settings and associated documentation.
- system audit records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- System/network administrators.
- organizational personnel with information security responsibilities.
- organizational personnel installing, configuring, and/or maintaining the system.
Test
Select from:
- Mechanisms supporting and/or implementing sensor relocation.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-48
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Not included |
Reference
Referenced Publications
1 Ross RS, Pillitteri VY, Graubart R, Bodeau D, McQuaid R (2019) Developing Cyber Resilient Systems: A Systems Security Engineering Approach. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-160, Vol. 2. https://doi.org/10.6028/NIST.SP.800-160v2