NIST SP 800-53r5 — PL-09 Central Management
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "PL-09"
family_id: "PL"
family: "Planning"
title: "Central Management"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: true
related_controls:
- "PL-08"
- "PM-09"
PL-09 Central Management
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Centrally manage [Assignment: organization-defined controls and related processes].
Discussion
Central management refers to organization-wide management and implementation of selected controls and processes. This includes planning, implementing, assessing, authorizing, and monitoring the organization-defined, centrally managed controls and processes. As the central management of controls is generally associated with the concept of common (inherited) controls, such management promotes and facilitates standardization of control implementations and management and the judicious use of organizational resources. Centrally managed controls and processes may also meet independence requirements for assessments in support of initial and ongoing authorizations to operate and as part of organizational continuous monitoring. Automated tools (e.g., security information and event management tools or enterprise security monitoring and management tools) can improve the accuracy, consistency, and availability of information associated with centrally managed controls and processes. Automation can also provide data aggregation and data correlation capabilities; alerting mechanisms; and dashboards to support risk-based decision-making within the organization. As part of the control selection processes, organizations determine the controls that may be suitable for central management based on resources and capabilities. It is not always possible to centrally manage every aspect of a control. In such cases, the control can be treated as a hybrid control with the control managed and implemented centrally or at the system level. The controls and control enhancements that are candidates for full or partial central management include but are not limited to: NIST SP 800-53r5 AC-02(01), NIST SP 800-53r5 AC-02(02), NIST SP 800-53r5 AC-02(03), NIST SP 800-53r5 AC-02(04), NIST SP 800-53r5 AC-04, NIST SP 800-53r5 AC-17(01), NIST SP 800-53r5 AC-17(02), NIST SP 800-53r5 AC-17(03), NIST SP 800-53r5 AC-17(09), NIST SP 800-53r5 AC-18(01), NIST SP 800-53r5 AC-18(03), NIST SP 800-53r5 AC-18(04), NIST SP 800-53r5 AC-18(05), NIST SP 800-53r5 AC-19(04), NIST SP 800-53r5 AC-22, NIST SP 800-53r5 AC-23, NIST SP 800-53r5 AT-02(01), NIST SP 800-53r5 AT-02(02), NIST SP 800-53r5 AT-03(01), NIST SP 800-53r5 AT-03(02), NIST SP 800-53r5 AT-03(03), NIST SP 800-53r5 AT-04, NIST SP 800-53r5 AU-03, NIST SP 800-53r5 AU-06(01), NIST SP 800-53r5 AU-06(03), NIST SP 800-53r5 AU-06(05), NIST SP 800-53r5 AU-06(06), NIST SP 800-53r5 AU-06(09), NIST SP 800-53r5 AU-07(01), NIST SP 800-53r5 AU-07(02), NIST SP 800-53r5 AU-11, NIST SP 800-53r5 AU-13, NIST SP 800-53r5 AU-16, NIST SP 800-53r5 CA-02(01), NIST SP 800-53r5 CA-02(02), NIST SP 800-53r5 CA-02(03), NIST SP 800-53r5 CA-03(01), NIST SP 800-53r5 CA-03(02), NIST SP 800-53r5 CA-03(03), NIST SP 800-53r5 CA-07(01), NIST SP 800-53r5 CA-09, NIST SP 800-53r5 CM-02(02), NIST SP 800-53r5 CM-03(01), NIST SP 800-53r5 CM-03(04), NIST SP 800-53r5 CM-04, NIST SP 800-53r5 CM-06, NIST SP 800-53r5 CM-06(01), NIST SP 800-53r5 CM-07(02), NIST SP 800-53r5 CM-07(04), NIST SP 800-53r5 CM-07(05), NIST SP 800-53r5 CM-08, NIST SP 800-53r5 CM-09(01), NIST SP 800-53r5 CM-10, NIST SP 800-53r5 CM-11, NIST SP 800-53r5 CP-07, NIST SP 800-53r5 CP-08, NIST SP 800-53r5 SC-43, NIST SP 800-53r5 SI-02, NIST SP 800-53r5 SI-03, NIST SP 800-53r5 SI-04, NIST SP 800-53r5 SI-07, NIST SP 800-53r5 SI-08.
Related Controls
- PL-08
- PM-09
Supporting Publications
- OMB A-1301
- SP 800-372
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
PL-09_ODP— security and privacy controls and related processes to be centrally managed are defined; -
PL-09— <PL-09_ODPcontrols and related processes> are centrally managed.
Potential Assessment Methods and Objects
Examine
Select from:
- Security and privacy planning policy.
- procedures addressing security and privacy plan development and implementation.
- system security plan.
- privacy plan.
- other relevant documents or records.
Interview
Select from:
- Organizational personnel with security and privacy planning and plan implementation responsibilities.
- organizational personnel with responsibilities for planning/implementing central management of controls and related processes.
- organizational personnel with information security and privacy responsibilities.
Test
Select from:
- Organizational processes for the central management of controls and related processes.
- mechanisms supporting and/or implementing central management of controls and related processes.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 PL-09
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Included |
Reference
- NIST SP 800-53B baseline tables
Referenced Publications
1 Office of Management and Budget Memorandum Circular A-130, Managing Information as a Strategic Resource, July 2016. https://www.whitehouse.gov/sites/whitehouse.gov/files/omb/circulars/A130/a130revised.pdf
2 Joint Task Force (2018) Risk Management Framework for Information Systems and Organizations: A System Life Cycle Approach for Security and Privacy. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-37, Rev. 2. https://doi.org/10.6028/NIST.SP.800-37r2