Open in TheBrain

CMMC 2.0 — SC.L3-03.13.10E Separate Subnetworks


source: false

type: canonical-control-reference

standard: CMMC 2.0

profile: "Level 3 additive SP 800-172r3 project baseline"

regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"

document_version: "SP 800-172r3 project baseline"

level: 3

practice_id: "SC.L3-03.13.10E"

source_requirement_id: "03.13.10E"

family_id: "03.13"

domain_id: "SC"

family: "System and Communications Protection"

title: "Separate Subnetworks"

status: active

baseline_mode: additive

level_2_prerequisite: true

level_2_controls_duplicated: false

scoring_method: "one-point-per-additional-requirement project assumption"

point_value: 1

assessment_reevaluation: conditional

assessment_poam_eligible: "not-defined-for-project-baseline"

deferred_documentation: "re-evaluation-only"

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-172r3 verified transcription"

- "NIST SP 800-172Ar3 verified transcription"

- "32 CFR Part 170 CMMC Program Final Rule"

canonical_source_card: "NIST SP 800-172r3 03.13.10E"

source_controls:

- "NIST SP 800-53r5 SC-07(22)"

source_assessment_procedures:

- "NIST SP 800-53Ar5 SC-07(22)"


SC.L3-03.13.10E Separate Subnetworks

Project-defined additive Level 3 profile

This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.

CMMC Level 3 — Additive Profile

Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.

NIST SP 800-172r3 — Enhanced Security Requirement

Implement separate network addresses to connect to systems in different security domains.

Discussion

The decomposition of systems into subnetworks (i.e., subnets) helps to provide the appropriate level of protection for network connections to different security domains. This requirement enhances SP 800-171 requirement 03.13.01.

Protection Strategy

PRA

Adversary Effects

Preclude (Preempt), Impede (Exert), Limit (Reduce)

References

Source Controls — NIST SP 800-53r5

NIST SP 800-172Ar3 — Assessment Procedure

Assessment Objective

Determine if:

A.03.13.10E: separate network addresses are implemented to connect to systems in different security domains.

Assessment Methods and Objects

Examine

[SELECT FROM: System and communications protection policy; procedures addressing boundary protection; system design documentation; system hardware and software; system architecture; system configuration settings and associated documentation; system audit records; system security plan; other relevant documents or records].

Interview

[SELECT FROM: System/network administrators; personnel with information security responsibilities; system developers; personnel with boundary protection responsibilities].

Test

[SELECT FROM: Mechanisms supporting and/or implementing separate network addresses or different subnets].

References

Source Assessment Procedures — NIST SP 800-53Ar5