CPCPC — 03.13.01 Boundary protection
source: false
type: canonical-control-reference
standard: Canadian Program for Cyber Security Certification
program_level: "Level 1"
control_id: "03.13.01"
family: "System and communications protection"
title: "Boundary protection"
status: active
updated: 2026-09-10
authoritative_sources:
- "ITSP.10.171"
03.13.01 Boundary protection
Canonical CPCSC Level 1 reference
Requirement text and discussion come from ITSP.10.171; assessment criteria come from the official CPCSC Level 1 criteria.
ITSP.10.171 — Requirement
-
03.13.01.AMonitor and control communications at the external managed interfaces to the system and key internal managed interfaces within the system
-
03.13.01.BImplement subnetworks for publicly accessible system components that are physically or logically separated from internal networks
-
03.13.01.CConnect to external systems only through managed interfaces consisting of boundary protection devices arranged in accordance with an organizational security architecture
Discussion
Managed interfaces include gateways, routers, firewalls, network-based malicious code analysis, virtualization systems, and encrypted tunnels implemented within a security architecture. Subnetworks that are either physically or logically separated from internal networks are referred to as demilitarized zones or DMZs. Restricting or prohibiting interfaces within organizational systems includes restricting external web traffic to designated web servers within managed interfaces, prohibiting both internal and external address spoofing for protocols crossing the boundary.
ITSP References
- Source control: SC-07 Supporting publications:
- Cyber Centre Baseline Security Requirements for Network Security Zones (ITSP.80.022) Cyber Centre Network security zoning – Design considerations for placement of services within zones (ITSG-38) Cyber Centre Guidance on Securely Configuring Network Protocols (ITSP.40.062) NIST SP 800-189 Resilient Interdomain Traffic Exchange: BGP Security and DDoS Mitigation NIST SP 800-41 Guidelines on Firewalls and Firewall Policy NIST SP 800-160-1 Engineering Trustworthy Secure Systems NIST SP 800-125B Secure Virtual Network Configuration for Virtual Machine (VM) Protection NIST SP 800-207 Zero Trust Architecture
CPCSC Level 1 — Assessment Procedure
Determine if
-
A.03.13.01.a[01]— communications at external managed interfaces to the system are monitored
-
A.03.13.01.a[02]— communications at external managed interfaces to the system are controlled
-
A.03.13.01.a[03]— communications at key internal managed interfaces within the system are monitored
-
A.03.13.01.a[04]— communications at key internal managed interfaces within the system are controlled
-
A.03.13.01.b— subnetworks are implemented for publicly accessible system components that are physically or logically separated from internal networks
-
A.03.13.01.c— external system connections are only made through managed interfaces that consist of boundary protection devices arranged in accordance with an organizational security architecture
Potential assessment methods and objects
Examine
Select from:
- system and communications protection policy and procedures
- procedures for boundary protection
- list of key internal boundaries within the system
- boundary protection hardware and software
- system configuration settings
- security architecture
- system audit records
- system design documentation
- enterprise security architecture documentation
- system security plan
- other relevant documents or records
Interview
Select from:
- personnel with boundary protection responsibilities
- personnel with information security responsibilities
- system developers
- system administrators
Test
Select from:
- mechanisms for implementing boundary protection capabilities
References
Source assessment procedure — NIST SP 800-53Ar5: SC-07
Source References
- ITSP.10.171 verified web transcription
- ITSP.10.171 official PDF
- CPCSC Level 1 criteria verified web transcription
Source Fidelity Notes
- Requirement prose uses the retained ITSP.10.171 HTML snapshot; original uppercase and numeric clause labels are displayed as full identifiers. CPCSC assessment identifiers keep their original lowercase letters and bracketed suffixes. They are not silently equated or renumbered.
- Literal
<A.…ODP…>references in malformed publisher HTML are escaped and displayed as code so parameter identifiers are not lost as HTML tags. No parameter value has been supplied locally.