CMMC 2.0 — SC.L3-03.13.13E Port and Input - Output Device Access
source: false
type: canonical-control-reference
standard: CMMC 2.0
profile: "Level 3 additive SP 800-172r3 project baseline"
regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"
document_version: "SP 800-172r3 project baseline"
level: 3
practice_id: "SC.L3-03.13.13E"
source_requirement_id: "03.13.13E"
family_id: "03.13"
domain_id: "SC"
family: "System and Communications Protection"
title: "Port and Input/Output Device Access"
status: active
baseline_mode: additive
level_2_prerequisite: true
level_2_controls_duplicated: false
scoring_method: "one-point-per-additional-requirement project assumption"
point_value: 1
assessment_reevaluation: conditional
assessment_poam_eligible: "not-defined-for-project-baseline"
deferred_documentation: "re-evaluation-only"
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-172r3 verified transcription"
- "NIST SP 800-172Ar3 verified transcription"
- "32 CFR Part 170 CMMC Program Final Rule"
canonical_source_card: "NIST SP 800-172r3 03.13.13E"
source_controls:
- "NIST SP 800-53r5 SC-41"
source_assessment_procedures:
- "NIST SP 800-53Ar5 SC-41"
SC.L3-03.13.13E Port and Input/Output Device Access
Project-defined additive Level 3 profile
This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.
CMMC Level 3 — Additive Profile
- Level 2 prerequisite: All Level 2 requirements remain prerequisites and are maintained only in CMMC 2.0 Level 2. They are not duplicated in this folder.
- Additional requirement source: NIST SP 800-172r3 03.13.13E.
- Point value: 1 point under this project profile, following the current CMMC Level 3 one-point-per-additional-requirement model.
- In-assessment correction / re-evaluation: Conditionally permitted for a NOT MET Level 3 requirement during the assessment and for 10 business days following the active assessment period, when additional evidence demonstrates MET, does not materially affect previously assessed requirements, and is provided before the Assessment Findings Report is delivered.
- Assessment POA&M: Not assigned at the individual-card level. The current regulatory exclusion list applies to the legacy 24-requirement CMMC v2.13 selection and cannot be accurately projected onto the complete SP 800-172r3 catalog without an approved successor mapping.
- Deferred documentation: No separate deferred-documentation finding is assumed. Draft, unofficial, or unapproved documentation is not acceptable evidence; corrections are handled through re-evaluation.
Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.
NIST SP 800-172r3 — Enhanced Security Requirement
[Selection (one): Physically; Logically] disable or remove [Assignment: organization-defined connection ports or input/output devices] on the following systems or system components: [Assignment: organization-defined systems or system components].
Discussion
Connection ports include Universal Serial Bus (USB), Thunderbolt, and Firewire (IEEE 1394). Input/output (I/O) devices include optical drives (e.g., compact disc and digital versatile disc drives), printers, and network-attached storage devices. Disabling or removing such connection ports and I/O devices helps prevent the exfiltration of information from systems and the introduction of malicious code from those ports or devices. Physically disabling or removing ports and/or devices is the stronger action. This requirement does not enhance a specific requirement in SP 800-171 but can be used to strengthen the protection of CUI associated with critical programs or high value assets.
Protection Strategy
PRA
Adversary Effects
Preclude (Preempt), Impede (Contain)
References
Source Controls — NIST SP 800-53r5
NIST SP 800-172Ar3 — Assessment Procedure
Assessment Objective
Determine if:
A.03.13.13E.ODP[01]: connection ports or input/output devices to be disabled or removed are defined.
A.03.13.13E.ODP[02]: one of the following PARAMETER VALUES is selected: {physically; logically}.
A.03.13.13E.ODP[03]: systems or system components with connection ports or input/output devices to be disabled or removed are defined.
A.03.13.13E: <A.03.13.13E.ODP[01]: connection ports or input/output devices> are <A.03.13.13E.ODP[02]: SELECTED PARAMETER VALUE> disabled or removed on <A.03.13.13E.ODP[03]: systems or system components>.
Assessment Methods and Objects
Examine
[SELECT FROM: System and communications protection policy; access control policy and procedures; procedures addressing port and input/output device access; system design documentation; system architecture; system configuration settings and associated documentation; systems or system components; list of connection ports or input/output devices to be physically disabled or removed on systems or system components; system security plan; other relevant documents or records].
Interview
[SELECT FROM: System/network administrators; personnel with information security responsibilities; personnel installing, configuring, and/or maintaining the system].
Test
[SELECT FROM: Mechanisms supporting and/or implementing the disabling of connection ports or input/output devices].
References
Source Assessment Procedure: SC-41
References
Source Assessment Procedures — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-41