Open in TheBrain

CMMC 2.0 — AC.L2-3.1.11 Session Termination


source: false

type: canonical-control-reference

standard: CMMC 2.0

document_version: "2.13"

level: 2

practice_id: "AC.L2-3.1.11"

family_id: "AC"

family: "Access Control"

title: "Session Termination"

status: active

scoring_method: weighted-deduction

point_value: 1

assessment_reevaluation: conditional

assessment_poam_eligible: true

deferred_documentation: "re-evaluation-only"

updated: 2026-09-10

authoritative_sources:

- "CMMC Level 2 Assessment Guide v2.13 transcription"

- "CMMC Level 2 Assessment Guide v2.13 PDF"

- "CMMC Model Overview v2.13"

- "CMMC Assessment Process (CAP), Version 2.0"

- "32 CFR Part 170 CMMC Program Final Rule"


AC.L2-3.1.11 Session Termination

Canonical CMMC 2.0 reference

Complete practice guidance comes from the official CMMC Level 2 Assessment Guide, Version 2.13.

CMMC 2.0 — Practice

Terminate (automatically) a user session after a defined condition.

Assessment Scoring and Correction

Sources: CAP v2.0, § 2.15; 32 CFR Part 170, §§ 170.17(c)(2), 170.21, and 170.24.

Assessment Objectives — NIST SP 800-171A1

Determine if:

Potential Assessment Methods and Objects — NIST SP 800-171A1

Examine

Select from:

Interview

Select from:

Test

Select from:

Discussion — NIST SP 800-171r22

This requirement addresses the termination of user-initiated logical sessions in contrast to the termination of network connections that are associated with communications sessions (i.e., disconnecting from the network). A logical session (for local, network, and remote access) is initiated whenever a user (or process acting on behalf of a user) accesses an organizational system. Such user sessions can be terminated (and thus terminate user access) without terminating network sessions. Session termination terminates all processes associated with a user’s logical session except those processes that are specifically created by the user (i.e., session owner) to continue after the session is terminated. Conditions or trigger events requiring automatic session termination can include organization-defined periods of user inactivity, targeted responses to certain types of incidents, and time-of-day restrictions on system use.

Further Discussion

Configure the system to terminate user sessions based on the organization’s policy. Session termination policies can be simple or sophisticated. Examples are inactivity (end the session after a specified duration (e.g., one hour 33) of inactivity), day/time (all sessions are terminated at the end of the established workday), misbehavior (end the session due to an attempted policy violation), and maintenance (terminate sessions to prevent issues with an upgrade or service outage). If there is no automatic control of user sessions, an attacker can take advantage of an unattended session.

Example 1

You manage systems containing CUI for your organization and configure the system to terminate all user sessions after 1 hour of inactivity [a]. As the session timeout approaches, the system prompts users with a warning banner asking if they want to continue the session. When the session timeout does occur, the login page pops up, and the users must log in to start a new session [b].

Example 2

A user is logged into a corporate database containing CUI but is not authorized to view CUI. The user has submitted a series of queries that unintentionally violate policy, as they attempt to extract CUI that the user is not authorized to view [a]. The session terminates with a warning as a result of a violation of corporate policy [b]. The user must reestablish the session before being able to submit additional legitimate queries.

Potential Assessment Considerations

Key References

33 Review DoD Cybersecurity FAQ Q53.2 for information on minimum values.

Source References

Referenced Publications


1 NIST SP 800-171A, Assessing Security Requirements for Controlled Unclassified Information.

2 NIST SP 800-171 Revision 2, Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations.