Open in TheBrain

ISO IEC 27018 2025 — A.10.3 PII return, transfer and disposal


source: false

type: canonical-control-reference

standard: "ISO/IEC 27018"

document_version: "2025"

element_id: "A.10.3"

family_id: "A.10"

family: "Accountability"

title: "PII return, transfer and disposal"

status: active

assessment_criterion: true

reference_basis: "user-supplied licensed ISO canonical publication"

normative_text_included: true

source_location: "PDF pages 33–34; printed pages 25–26"

updated: 2026-09-11

scf_mappings: []

authoritative_sources:

- "ISO/IEC 27018:2025 canonical PDF"

text_kind: guidance

source_text_verified: true


A.10.3 PII return, transfer and disposal

Public Cloud PII Protection

a) Control

The public cloud PII processor should have a policy in respect of these activities and should make this policy available to the cloud service customer.

b) Public cloud PII protection implementation guidance

At some point in time, PII are expected to be disposed of in some manner. This can involve returning the PII to the cloud service customer, transferring it to another public cloud PII processor or to a PII controller (e.g. as a result of a merger), securely deleting or otherwise destroying it, anonymizing it or archiving it.

The public cloud PII processor should provide the information necessary to allow the cloud service customer to ensure that PII processed under a contract is erased (by the public cloud PII processor and any of its sub-contractors) from wherever they are stored, including for the purposes of backup and business continuity, as soon as they are no longer necessary for the specific purposes of the cloud service customer. The nature of the disposition mechanisms (de-linking, overwriting, demagnetization, destruction or other forms of erasure) and/or the applicable commercial standards should be provided for contractually.

The public cloud PII processor should develop and implement a policy in respect of the disposition of PII and should make this policy available to the cloud service customer.

The policy should cover the retention period for PII before its destruction after termination of a contract, to protect the cloud service customer from losing PII through an accidental lapse of the contract.

NOTE This control and guidance is also relevant under the retention element of the “Use, retention and disclosure limitation” principle (see A.6).

SCF Relationships

No relationship for this identifier was found in the supplied SCF STRM mapping.

Notes

References