NIST SP 800-53r5 — MA-04(06) Cryptographic Protection
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "MA-04(06)"
family_id: "MA"
family: "Maintenance"
title: "Cryptographic Protection"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: false
privacy: false
related_controls:
- "SC-08"
- "SC-12"
- "SC-13"
MA-04(06) Cryptographic Protection
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Implement the following cryptographic mechanisms to protect the integrity and confidentiality of nonlocal maintenance and diagnostic communications: [Assignment: organization-defined cryptographic mechanisms].
Discussion
Failure to protect nonlocal maintenance and diagnostic communications can result in unauthorized individuals gaining access to organizational information. Unauthorized access during remote maintenance sessions can result in a variety of hostile actions, including malicious code insertion, unauthorized changes to system parameters, and exfiltration of organizational information. Such actions can result in the loss or degradation of mission or business capabilities.
Related Controls
Supporting Publications
- None specified.
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
MA-04(06)_ODP— cryptographic mechanisms to be implemented to protect the integrity and confidentiality of nonlocal maintenance and diagnostic communications are defined; -
MA-04(06)[01]— <MA-04(06)_ODPcryptographic mechanisms> are implemented to protect the integrity of nonlocal maintenance and diagnostic communications; -
MA-04(06)[02]— <MA-04(06)_ODPcryptographic mechanisms> are implemented to protect the confidentiality of nonlocal maintenance and diagnostic communications.
Potential Assessment Methods and Objects
Examine
Select from:
- Maintenance policy.
- procedures addressing nonlocal system maintenance.
- system design documentation.
- system configuration settings and associated documentation.
- cryptographic mechanisms protecting nonlocal maintenance activities.
- maintenance records.
- diagnostic records.
- audit records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- Organizational personnel with system maintenance responsibilities.
- network engineers.
- organizational personnel with information security responsibilities.
- system/network administrators.
Test
Select from:
- Cryptographic mechanisms protecting nonlocal maintenance and diagnostic communications.
References
Source Assessment Procedure — NIST SP 800-53Ar5
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Not included |
| Privacy | Not included |