Open in TheBrain

CPCPC — 03.10.07 Physical access control


source: false

type: canonical-control-reference

standard: Canadian Program for Cyber Security Certification

program_level: "Level 1"

control_id: "03.10.07"

family: "Physical protection"

title: "Physical access control"

status: active

updated: 2026-09-10

authoritative_sources:

- "ITSP.10.171"

- "CPCSC Level 1 criteria"


03.10.07 Physical access control

Canonical CPCSC Level 1 reference

Requirement text and discussion come from ITSP.10.171; assessment criteria come from the official CPCSC Level 1 criteria.

ITSP.10.171 — Requirement

- 03.10.07.A.1 verifying individual physical access authorizations before granting access to the facility

- 03.10.07.A.2 controlling ingress and egress with physical access control systems, devices or guards

Discussion

This requirement addresses physical locations containing systems or system components that process, store, or transmit specified information. Organizations determine the types of guards needed, including professional security staff or administrative staff. Physical access devices include keys, locks, combinations, biometric readers, and card readers. Physical access control systems comply with applicable laws, Orders in Council, directives, policies, regulations, standards, and guidelines. Organizations have flexibility in the types of audit logs employed. Audit logs can be procedural, automated, or some combination thereof. Physical access points can include exterior access points, interior access points to systems that require supplemental access controls, or both. Physical access control applies to employees and visitors. Individuals with permanent physical access authorizations are not considered visitors.

Controlling physical access to output devices includes placing output devices in locked rooms or other secured areas with keypad or card reader access controls and only allowing access to authorized individuals, placing output devices in locations that can be monitored by personnel, installing monitor or screen filters, and using headphones. Examples of output devices include monitors, printers, scanners, facsimile machines, audio devices, and copiers.

ITSP References

CPCSC Level 1 — Assessment Procedure

Determine if

Potential assessment methods and objects

Examine

Select from:

Interview

Select from:

Test

Select from:

References

Source assessment procedure — NIST SP 800-53Ar5: PE-03, PE-05

Source References

Source Fidelity Notes