NIST SP 800-53r5 — SC-03 Security Function Isolation
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "SC-03"
family_id: "SC"
family: "System and Communications Protection"
title: "Security Function Isolation"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: false
high: true
privacy: false
related_controls:
- "AC-03"
- "AC-06"
- "AC-25"
- "CM-02"
- "CM-04"
- "SA-04"
- "SA-05"
- "SA-08"
- "SA-15"
- "SA-17"
- "SC-02"
- "SC-07"
- "SC-32"
- "SC-39"
- "SI-16"
SC-03 Security Function Isolation
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
Isolate security functions from nonsecurity functions.
Discussion
Security functions are isolated from nonsecurity functions by means of an isolation boundary implemented within a system via partitions and domains. The isolation boundary controls access to and protects the integrity of the hardware, software, and firmware that perform system security functions. Systems implement code separation in many ways, such as through the provision of security kernels via processor rings or processor modes. For non-kernel code, security function isolation is often achieved through file system protections that protect the code on disk and address space protections that protect executing code. Systems can restrict access to security functions using access control mechanisms and by implementing least privilege capabilities. While the ideal is for all code within the defined security function isolation boundary to only contain security-relevant code, it is sometimes necessary to include nonsecurity functions as an exception. The isolation of security functions from nonsecurity functions can be achieved by applying the systems security engineering design principles in NIST SP 800-53r5 SA-08, including NIST SP 800-53r5 SA-08(01), NIST SP 800-53r5 SA-08(03), NIST SP 800-53r5 SA-08(04), NIST SP 800-53r5 SA-08(10), NIST SP 800-53r5 SA-08(12), NIST SP 800-53r5 SA-08(13), NIST SP 800-53r5 SA-08(14), and NIST SP 800-53r5 SA-08(18).
Related Controls
Supporting Publications
- None specified.
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
SC-03— security functions are isolated from non-security functions.
Potential Assessment Methods and Objects
Examine
Select from:
- System and communications protection policy.
- procedures addressing security function isolation.
- list of security functions to be isolated from non-security functions.
- system design documentation.
- system configuration settings and associated documentation.
- system audit records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- System/network administrators.
- organizational personnel with information security responsibilities.
- system developer.
Test
Select from:
- Separation of security functions from non-security functions within the system.
References
Source Assessment Procedure — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 SC-03
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Not included |
| High | Included |
| Privacy | Not included |