Open in TheBrain

NIST SP 800-172 — 3.13.4e


source: false

type: canonical-control-reference

standard: NIST SP 800-172

assessment_standard: NIST SP 800-172A

control_id: "3.13.4e"

family_id: "3.13"

family: "System and Communications Protection"

title: "Employ [Selection: (one or more): [Assignment: organization-defined physical isolation techniques]; [Assignment: organization-defined logical isolation techniques]] in organizational systems and system components."

status: active

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-172 verified transcription"

- "NIST SP 800-172A verified transcription"

source_controls:

- "NIST SP 800-53r5 SC-07"

- "NIST SP 800-53r5 SC-07(13)"

- "NIST SP 800-53r5 SC-07(21)"

- "NIST SP 800-53r5 SC-07(22)"

- "NIST SP 800-53r5 SC-25"

source_assessment_procedures:

- "NIST SP 800-53Ar5 SC-07"

- "NIST SP 800-53Ar5 SC-07(13)"

- "NIST SP 800-53Ar5 SC-07(21)"

- "NIST SP 800-53Ar5 SC-07(22)"

- "NIST SP 800-53Ar5 SC-25"


3.13.4e

Canonical combined reference

Requirement text comes from NIST SP 800-172. Assessment procedures come from NIST SP 800-172A. Assessment identifiers retain their NIST-defined bracket and dot syntax.

NIST SP 800-172 — Enhanced Security Requirement

Employ [Selection: (one or more): [Assignment: organization-defined physical isolation techniques]; [Assignment: organization-defined logical isolation techniques]] in organizational systems and system components.

Discussion

A mix of physical and logical isolation techniques (described below) implemented as part of the system architecture can limit the unauthorized flow of CUI, reduce the system attack surface, constrain the number of system components that must be secure, and impede the movement of an adversary. When implemented with a set of managed interfaces, physical and logical isolation techniques for organizational systems and components can isolate CUI into separate security domains where additional protections can be implemented. Any communications across the managed interfaces (i.e., across security domains), including for management or administrative purposes, constitutes remote access even if the communications remain within the organization. Separating system components with boundary protection mechanisms allows for the increased protection of individual components and more effective control of information flows between those components. This enhanced protection limits the potential harm from and susceptibility to hostile cyber-attacks and errors. The degree of isolation can vary depending on the boundary protection mechanisms selected. Boundary protection mechanisms include routers, gateways, and firewalls separating system components into physically separate networks or subnetworks; virtualization and micro-virtualization techniques; encrypting information flows among system components using distinct encryption keys; cross-domain devices separating subnetworks; and complete physical separation (i.e., air gaps).

System architectures include logical isolation, partial physical and logical isolation, or complete physical isolation between subsystems and at system boundaries between resources that store, process, transmit, or protect CUI and other resources. Examples include:

Isolation techniques are selected based on a risk management perspective that balances the threat, the information being protected, and the cost of the options for protection. Architectural and design decisions are guided and informed by the security requirements and selected solutions. Organizations consider the trustworthiness of the isolation techniques employed (e.g., the logical isolation relies on information technology that could be considered a high value target because of the function being performed), introducing its own set of vulnerabilities.

SP 800-160-11 provides guidance on developing trustworthy, secure, and cyber resilient systems using systems security engineering practices and security design concepts.

Protection Strategy

Penetration-Resistant Architecture; Designing for Cyber Resiliency and Survivability.

Adversary Effects

See SP 800-160-22: [Preclude (Preempt, Negate); Impede (Contain, Degrade, Delay, Exert); Limit (Reduce)].

References

Source Controls — NIST SP 800-53r5
Supporting Publications

NIST SP 800-172A — Assessment Procedure

Employ [Selection: (one or more): [Assignment: organization-defined physical isolation techniques]; [Assignment: organization-defined logical isolation techniques]] in organizational systems and system components.

Assessment Objective

Determine if:

Assessment Methods and Objects

Examine

Select from:

Interview

Select from:

Test

Select from:

References

Source Assessment Procedures — NIST SP 800-53Ar5

Referenced Publications


1 Systems Security Engineering: Considerations for a Multidisciplinary Approach in the Engineering of Trustworthy Secure Systems NIST Special Publication (SP) 800-160, Vol. 1, Includes updates as of March 21, 2018 Ross RS, Oren JC, McEvilley M (2016), National Institute of Standards and Technology, Gaithersburg, MD https://doi.org/10.6028/NIST.SP.800-160v1

2 Systems Security Engineering: Cyber Resiliency Considerations for the Engineering of Trustworthy Secure Systems NIST Special Publication (SP) 800-160, Vol. 2 Ross RS, Graubart R, Bodeau D, McQuaid R (2019), National Institute of Standards and Technology, Gaithersburg, MD https://doi.org/10.6028/NIST.SP.800-160v2