NIST SP 800-53r5 — AU-12(03) Changes by Authorized Individuals


source: false

type: canonical-control-reference

standard: NIST SP 800-53r5

assessment_standard: NIST SP 800-53Ar5

baseline_standard: NIST SP 800-53B

control_id: "AU-12(03)"

family_id: "AU"

family: "Audit and Accountability"

title: "Changes by Authorized Individuals"

status: active

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-53r5 verified transcription"

- "NIST SP 800-53Ar5 verified transcription"

- "NIST SP 800-53B verified transcription"

baseline_membership:

low: false

moderate: false

high: true

privacy: false

related_controls:

- "AC-03"


AU-12(03) Changes by Authorized Individuals

Canonical combined reference

Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.

NIST SP 800-53r5 — Control

Provide and implement the capability for [Assignment: organization-defined individuals or roles] to change the logging to be performed on [Assignment: organization-defined system components] based on [Assignment: organization-defined selectable event criteria] within [Assignment: organization-defined time thresholds].

Discussion

Permitting authorized individuals to make changes to system logging enables organizations to extend or limit logging as necessary to meet organizational requirements. Logging that is limited to conserve system resources may be extended (either temporarily or permanently) to address certain threat situations. In addition, logging may be limited to a specific set of event types to facilitate audit reduction, analysis, and reporting. Organizations can establish time thresholds in which logging actions are changed (e.g., near real-time, within minutes, or within hours).

Related Controls

Supporting Publications

NIST SP 800-53Ar5 — Assessment Procedure

Assessment Objective

Determine if:

Potential Assessment Methods and Objects

Examine

Select from:

Interview

Select from:

Test

Select from:

References

Source Assessment Procedure — NIST SP 800-53Ar5

NIST SP 800-53B — Baseline Membership

Baseline Membership


Low Not included
Moderate Not included
High Included
Privacy Not included

Reference