PES-01.2 Zone-Based Physical Security
Canonical SCF 2026.2 reference
Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.
Source and mapping limits
This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.
SCF 2026.2 — Control
Mechanisms exist to implement a zone-based approach to physical security.
Domain Principle
Physical & Environmental Security (PES): Protect physical environments through layered physical security and environmental controls that safeguard physical and digital assets from unauthorized access, theft, damage and disruption.
Organizations limit physical access to Technology Assets, Applications, Services and Data (TAASD) and monitor environmental conditions commensurate with risk to prevent unauthorized access and reduce equipment failure, damage or disruption from physical and environmental threats.
Control Question
Does the organization implement a zone-based approach to physical security?
Operational Metadata
| Field | Value |
|---|---|
| Conformity validation cadence | Annual |
| Relative control weighting | 3 |
| PPTDF applicability | Process |
| NIST CSF function grouping | Protect |
Possible Solutions & Considerations
Micro-Small Business
- Physical security policy with basic controls documented
Small Business
- Documented physical security procedures
- Review annually
Medium Business
- Formal physical security procedures for all zones
- Training for relevant staff
Large Business
- Enterprise physical security procedures
- Regular drills and exercises
Enterprise
- Enterprise physical security program with comprehensive procedures
- Regular exercises and audits
- Third-party security assessments
Assessment Objectives
PES-01.2_A01
a zone-based approach to physical security is developed.
PPTDF applicability:
- Facility
Origin(s):
-
SCF Created
Assessment rigor:
- 1
PES-01.2_A02
a zone-based approach to physical security is implemented.
PPTDF applicability:
- Facility
Origin(s):
-
SCF Created
Assessment rigor:
- 1
Evidence Requests
-
E-PES-11— Physical Security Zones (Physical Security): Documented evidence of security safeguards controlling access to designated physical security zones within facilities.
Compensating Controls
Risk if Primary Control Is Not Implemented
Without Zone-Based Physical Security, unauthorized physical access to facilities may enable theft, tampering, or direct attacks on infrastructure.
Possible Compensating Control 1
PES-03 — Physical Access Control
Physical access control mechanisms exist to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).
Justification:
Physical Access Control (PES-03) provides access control enforcement that compensates for the absence of Zone-Based Physical Security (PES-01.2) by restricting system and data access to authorized users through alternative identity and access mechanisms. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Possible Compensating Control 2
PES-05 — Monitoring Physical Access
Physical access control mechanisms exist to monitor for, detect and respond to physical security incidents.
Justification:
Monitoring Physical Access (PES-05) provides detective monitoring capability that compensates for the absence of Zone-Based Physical Security (PES-01.2) by identifying unauthorized, anomalous, or non-compliant activity that the primary control would have prevented. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Applicability and Profile Membership
- SCRM Focus TIER 2 OPERATIONAL: Included
- SCR-CMM Level 0 Not Performed:
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
- SCR-CMM Level 1 Performed Informally:
Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include:
- Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation.
- Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices.
- Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs).
- IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.
- SCR-CMM Level 2 Planned & Tracked:
SCR-CMM Level 2 criteria definitions are not available for this control:
- A reasonable person would conclude a well-defined and standardized process is required.
- At this level of maturity, the “requirements-driven” nature of performing the control is focused on a localized and/or regionalized implementation, not uniform and consistent across the organization.
- Requirements are narrowly scoped for applicability and are primarily derived from compliance obligations (e.g., laws, regulations and contracts).
- SCR-CMM Level 3 Well Defined:
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.
- Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners.
- A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities.
- Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation, proximity badge access, etc.).
- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).
- An implemented and operational capability exists to implement a zone-based approach to physical security.
- SCR-CMM Level 4 Quantitatively Controlled:
Utilize SCR-CMM Level 3 criteria definitions:
- There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control.
- While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define.
- SCR-CMM Level 5 Continuously Improving:
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:
- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.
- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.
- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
- SCF SCRMS: PES-01.2
Framework Mappings
- Trusted Information Security Assessment Exchange (TISAX) 6.0.3:
3.1.1 - US - North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) (2024):
CIP-006-6 1.2 - Germany - Cloud Computing Compliance Controls Catalogue (C5) (2020):
PS-01-DOAR,PS-03-BP1
Minimum Security Requirements
- No MCR or DSR designation is specified in the source workbook.
Risk and Threat Mappings
Risks
-
R-AC-1 -
R-AC-2 -
R-AC-3 -
R-AC-4 -
R-AM-1 -
R-AM-2 -
R-BC-1 -
R-BC-2 -
R-BC-3 -
R-BC-4 -
R-BC-5 -
R-EX-1 -
R-EX-2 -
R-EX-3 -
R-EX-4 -
R-EX-5 -
R-EX-6 -
R-EX-7 -
R-GV-1 -
R-GV-2 -
R-GV-3 -
R-GV-4 -
R-GV-5 -
R-GV-6 -
R-GV-7 -
R-IR-1 -
R-IR-2 -
R-IR-3 -
R-IR-4 -
R-SA-1 -
R-SC-1 -
R-SC-2 -
R-SC-3 -
R-SC-4 -
R-SC-5 -
R-SC-6
Threats
-
NT-7 -
MT-1 -
MT-2 -
MT-7 -
MT-8 -
MT-9 -
MT-10 -
MT-11 -
MT-12 -
MT-13 -
MT-14 -
MT-15 -
MT-24 -
MT-25 -
MT-27 -
MT-28
Source References
- Secure Controls Framework 2026.2 workbook
- SCF Overview & Practitioner Guidebook, version 2026.2