CMMC 2.0 — PE.L3-03.10.02E Delivery and Removal of System Components


source: false

type: canonical-control-reference

standard: CMMC 2.0

profile: "Level 3 additive SP 800-172r3 project baseline"

regulatory_status: "project-defined; not the current CMMC v2.13 Level 3 control selection"

document_version: "SP 800-172r3 project baseline"

level: 3

practice_id: "PE.L3-03.10.02E"

source_requirement_id: "03.10.02E"

family_id: "03.10"

domain_id: "PE"

family: "Physical Protection"

title: "Delivery and Removal of System Components"

status: active

baseline_mode: additive

level_2_prerequisite: true

level_2_controls_duplicated: false

scoring_method: "one-point-per-additional-requirement project assumption"

point_value: 1

assessment_reevaluation: conditional

assessment_poam_eligible: "not-defined-for-project-baseline"

deferred_documentation: "re-evaluation-only"

updated: 2026-09-10

authoritative_sources:

- "NIST SP 800-172r3 verified transcription"

- "NIST SP 800-172Ar3 verified transcription"

- "32 CFR Part 170 CMMC Program Final Rule"

canonical_source_card: "NIST SP 800-172r3 03.10.02E"

source_controls:

- "NIST SP 800-53r5 PE-16"

source_assessment_procedures:

- "NIST SP 800-53Ar5 PE-16"


PE.L3-03.10.02E Delivery and Removal of System Components

Project-defined additive Level 3 profile

This card applies the active NIST SP 800-172r3 enhanced requirement as an additional Level 3 requirement. It is not a representation of the current CMMC v2.13 selection of 24 NIST SP 800-172 (2021) requirements.

CMMC Level 3 — Additive Profile

Source for the scoring and re-evaluation model: 32 CFR Part 170, §§ 170.18(c)(2), 170.21, and 170.24(c)(3). Application to the complete SP 800-172r3 catalog is a project assumption.

NIST SP 800-172r3 — Enhanced Security Requirement

Discussion

Enforcing authorizations for the entry and exit of system components may require restricting access to delivery areas and isolating the areas from the system and media libraries. This requirement does not enhance a specific requirement in SP 800-171 but can be used to strengthen the protection of CUI associated with critical programs or high value assets.

Protection Strategy

PRA

Adversary Effects

Preclude (Preempt)

References

Source Controls — NIST SP 800-53r5

NIST SP 800-172Ar3 — Assessment Procedure

Assessment Objective

Determine if:

A.03.10.02E.ODP[01]: the types of system components to be authorized and controlled when entering the facility are defined.

A.03.10.02E.ODP[02]: the types of system components to be authorized and controlled when exiting the facility are defined.

A.03.10.02E.a[01]: <A.03.10.02E.ODP[01]: types of system components> are authorized when entering the facility.

A.03.10.02E.a[02]: <A.03.10.02E.ODP[01]: types of system components> are controlled when entering the facility.

A.03.10.02E.a[03]: <A.03.10.02E.ODP[02]: types of system components> are authorized when exiting the facility. A.03.10.02E.a[04]: <A.03.10.02E.ODP[02]: types of system components> are controlled when exiting the facility.

A.03.10.02E.b: records of the system components entering and exiting the facility are maintained.

Assessment Methods and Objects

Examine

[SELECT FROM: Physical and environmental protection policy; procedures addressing the delivery and removal of system components from the facility; facility housing the system; records of items entering and exiting the facility; system security plan; other relevant documents or records].

Interview

[SELECT FROM: Personnel with responsibilities for controlling system components entering and exiting the facility; personnel with information security responsibilities].

Test

[SELECT FROM: Process for authorizing, monitoring, and controlling system-related items entering and exiting the facility; mechanisms supporting and/or implementing, authorizing, monitoring, and controlling system components entering and exiting the facility].

References

Source Assessment Procedures — NIST SP 800-53Ar5