Open in TheBrain

Secure Controls Framework 2026.2 — PES-01 Physical & Environmental Protections


source: false

type: canonical-control-reference

standard: Secure Controls Framework 2026.2

control_id: "PES-01"

domain_id: "PES"

domain: "Physical & Environmental Security"

title: "Physical & Environmental Protections"

status: active

validation_cadence: "Annual"

relative_control_weighting: "9"

pptdf_applicability: "Process"

nist_csf_function: "Govern"

updated: 2026-09-10

authoritative_sources:

- "SCF 2026.2 workbook"

- "SCF Overview & Practitioner Guidebook, version 2026.2"

source_sheet: "SCF 2026.2"

source_row: 1062

source_workbook_sha256: "9e0a4df4993726c95e636f04b3028d8b5edeba2bda45d16ed6722b13540e6835"

source_fidelity_audit: "2026-09-13"


PES-01 Physical & Environmental Protections

Canonical SCF 2026.2 reference

Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.

Source and mapping limits

This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.

SCF 2026.2 — Control

Mechanisms exist to facilitate the operation of physical and environmental protection controls.

Domain Principle

Physical & Environmental Security (PES): Protect physical environments through layered physical security and environmental controls that safeguard physical and digital assets from unauthorized access, theft, damage and disruption.

Organizations limit physical access to Technology Assets, Applications, Services and Data (TAASD) and monitor environmental conditions commensurate with risk to prevent unauthorized access and reduce equipment failure, damage or disruption from physical and environmental threats.

Control Question

Does the organization facilitate the operation of physical and environmental protection controls?

Operational Metadata

Field Value


Conformity validation cadence Annual
Relative control weighting 9
PPTDF applicability Process
NIST CSF function grouping Govern

Possible Solutions & Considerations

Micro-Small Business

Small Business

Medium Business

Large Business

Enterprise

Assessment Objectives

PES-01_A01

the physical facility where organizational systems reside is protected.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-171A:

PES-01_A02

the location or site of the facility where the system resides is planned considering physical and environmental hazards.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-53A:

PES-01_A03

for existing facilities, physical and environmental hazards are considered in the organizational risk management strategy.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-53A:

PES-01_A04

the support infrastructure for organizational systems is protected.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-171A:

PES-01_A05

the physical facility where organizational systems reside is monitored.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-171A:

PES-01_A06

the support infrastructure for organizational systems is monitored.

PPTDF applicability:

Origin(s):

Assessment rigor:

NIST SP 800-171A:

PES-01_A07

physical security operations are conducted according to documented policies, standards, procedures and/or other organizational directives.

PPTDF applicability:

Origin(s):

Assessment rigor:

PES-01_A08

adequate resources (e.g., people, processes, technologies, data and/or facilities) are provided to support physical security operations.

PPTDF applicability:

Origin(s):

Assessment rigor:

PES-01_A09

responsibility and authority for the performance of physical security-related activities are assigned to designated personnel.

PPTDF applicability:

Origin(s):

Assessment rigor:

PES-01_A10

personnel performing physical security-related activities have the skills and knowledge needed to perform their assigned duties.

PPTDF applicability:

Origin(s):

Assessment rigor:

Evidence Requests

Compensating Controls

Risk if Primary Control Is Not Implemented

Without Physical & Environmental Protections, unauthorized physical access to facilities may enable theft, tampering, or direct attacks on infrastructure.

Possible Compensating Control 1

PES-03 — Physical Access Control

Physical access control mechanisms exist to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).

Justification:

Physical Access Control (PES-03) provides access control enforcement that compensates for the absence of Physical & Environmental Protections (PES-01) by restricting system and data access to authorized users through alternative identity and access mechanisms. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.

Possible Compensating Control 2

MON-01 — Continuous Monitoring

Mechanisms exist to facilitate the implementation of enterprise-wide monitoring controls.

Justification:

Continuous Monitoring (MON-01) provides detective monitoring capability that compensates for the absence of Physical & Environmental Protections (PES-01) by identifying unauthorized, anomalous, or non-compliant activity that the primary control would have prevented. Given the process-oriented nature of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.

Applicability and Profile Membership

Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.

Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include:

- Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation.

- Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices.

- Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs).

- IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.

Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist:

- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity.

- Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners.

- IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD).

- Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards, procedures & guidelines).

- Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel.

- Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.

- The Human Resources (HR) department maintains a current list of personnel with authorized access to organizational facilities and facilitates the implementation of physical access management controls.

- Physical security controls and technologies ensure that only authorized personnel are allowed access to secure areas.

- A facilities maintenance team, or similar function, manages the operation of automated physical and environmental protection controls.

Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:

- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.

- Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners.

- A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities.

- Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation, proximity badge access, etc.).

- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).

- An implemented and operational capability exists to facilitate the operation of physical and environmental protection controls.

Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist:

- Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational.

- Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs).

- Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs).

- Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties.

- Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review).

- Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes.

- Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.

Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:

- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.

- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.

- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.

Framework Mappings

Minimum Security Requirements

Risk and Threat Mappings

Risks

Threats

Source References