03.01.11 Session Termination
Canonical combined reference
Requirement text and discussion come from NIST SP 800-171r3. Assessment procedures come from NIST SP 800-171Ar3. Assessment identifiers and source-reference numbers retain their NIST-defined meaning.
NIST SP 800-171r3 — Security Requirement
Terminate a user session automatically after [Assignment: organization-defined conditions or trigger events requiring session disconnect].
Discussion
This requirement addresses the termination of user-initiated logical sessions in contrast to the termination of network connections that are associated with communications sessions (i.e., disconnecting from the network) in 03.13.09. A logical session is initiated whenever a user (or processes acting on behalf of a user) accesses a system. Logical sessions can be terminated (and thus terminate user access) without terminating network sessions. Session termination ends all system processes associated with a user's logical session except those processes that are created by the user (i.e., session owner) to continue after the session is terminated. Conditions or trigger events that require automatic session termination can include organization-defined periods of user inactivity, time-of-day restrictions on system use, and targeted responses to certain types of incidents.
References
Source Controls — NIST SP 800-53r5
- NIST SP 800-53r5 AC-12 — Session Termination
Supporting Publications
None.
NIST SP 800-171Ar3 — Assessment Procedure
Assessment Objective
Determine if:
-
A.03.01.11.ODP[01]— conditions or trigger events that require session disconnect are defined.
-
A.03.01.11— a user session is terminated automatically after<A.03.01.11.ODP[01]: conditions or trigger events>.
Assessment Methods and Objects
Examine
Select from:
- access control policy and procedures;
- procedures for session termination;
- system design documentation;
- system configuration settings;
- list of conditions or trigger events requiring session disconnect;
- system audit records;
- system security plan;
- other relevant documents or records.
Interview
Select from:
- personnel with information security responsibilities;
- system developers;
- system administrators.
Test
Select from:
- automated mechanisms for implementing user session termination.
References
Source Assessment Procedures — NIST SP 800-53Ar5
- NIST SP 800-53Ar5 AC-12 — Session Termination