NIST SP 800-53r5 — MA-03 Maintenance Tools
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "MA-03"
family_id: "MA"
family: "Maintenance"
title: "Maintenance Tools"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: false
moderate: true
high: true
privacy: false
related_controls:
- "MA-02"
- "PE-16"
MA-03 Maintenance Tools
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
- a. Approve, control, and monitor the use of system maintenance tools; and
- b. Review previously approved system maintenance tools [Assignment: organization-defined frequency].
Discussion
Approving, controlling, monitoring, and reviewing maintenance tools address security-related issues associated with maintenance tools that are not within system authorization boundaries and are used specifically for diagnostic and repair actions on organizational systems. Organizations have flexibility in determining roles for the approval of maintenance tools and how that approval is documented. A periodic review of maintenance tools facilitates the withdrawal of approval for outdated, unsupported, irrelevant, or no-longer-used tools. Maintenance tools can include hardware, software, and firmware items and may be pre-installed, brought in with maintenance personnel on media, cloud-based, or downloaded from a website. Such tools can be vehicles for transporting malicious code, either intentionally or unintentionally, into a facility and subsequently into systems. Maintenance tools can include hardware and software diagnostic test equipment and packet sniffers. The hardware and software components that support maintenance and are a part of the system (including the software implementing utilities such as "ping," "ls," "ipconfig," or the hardware and software implementing the monitoring port of an Ethernet switch) are not addressed by maintenance tools.
Related Controls
Supporting Publications
- SP 800-881
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
MA-03_ODP— frequency at which to review previously approved system maintenance tools is defined; -
MA-03a.[01]— the use of system maintenance tools is approved; -
MA-03a.[02]— the use of system maintenance tools is controlled; -
MA-03a.[03]— the use of system maintenance tools is monitored; -
MA-03b.— previously approved system maintenance tools are reviewed <MA-03_ODPfrequency>.
Potential Assessment Methods and Objects
Examine
Select from:
- Maintenance policy.
- procedures addressing system maintenance tools.
- system maintenance tools and associated documentation.
- maintenance records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- Organizational personnel with system maintenance responsibilities.
- organizational personnel with information security responsibilities.
Test
Select from:
- Organizational processes for approving, controlling, and monitoring maintenance tools.
- mechanisms supporting and/or implementing the approval, control, and/or monitoring of maintenance tools.
References
Source Assessment Procedure — NIST SP 800-53Ar5
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Not included |
| Moderate | Included |
| High | Included |
| Privacy | Not included |
Reference
Referenced Publications
1 Kissel RL, Regenscheid AR, Scholl MA, Stine KM (2014) Guidelines for Media Sanitization. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-88, Rev. 1. https://doi.org/10.6028/NIST.SP.800-88r1