CMMC 2.0 — SI.L2-3.14.4 Update Malicious Code Protection (CUI Data)


source: false

type: canonical-control-reference

standard: CMMC 2.0

document_version: "2.13"

level: 2

practice_id: "SI.L2-3.14.4"

family_id: "SI"

family: "System and Information Integrity"

title: "Update Malicious Code Protection [CUI Data]"

status: active

scoring_method: weighted-deduction

point_value: 5

assessment_reevaluation: conditional

assessment_poam_eligible: false

deferred_documentation: "re-evaluation-only"

updated: 2026-09-10

authoritative_sources:

- "CMMC Level 2 Assessment Guide v2.13 transcription"

- "CMMC Level 2 Assessment Guide v2.13 PDF"

- "CMMC Model Overview v2.13"

- "CMMC Assessment Process (CAP), Version 2.0"

- "32 CFR Part 170 CMMC Program Final Rule"


SI.L2-3.14.4 Update Malicious Code Protection [CUI Data]

Canonical CMMC 2.0 reference

Complete practice guidance comes from the official CMMC Level 2 Assessment Guide, Version 2.13.

CMMC 2.0 — Practice

Update malicious code protection mechanisms when new releases are available.

Assessment Scoring and Correction

Sources: CAP v2.0, § 2.15; 32 CFR Part 170, §§ 170.17(c)(2), 170.21, and 170.24.

Assessment Objectives — NIST SP 800-171A1

Determine if:

Potential Assessment Methods and Objects — NIST SP 800-171A1

Examine

Select from:

Interview

Select from:

Test

Select from:

Discussion — NIST SP 800-171r22

Malicious code protection mechanisms include anti-virus signature definitions and reputation-based technologies. A variety of technologies and methods exist to limit or eliminate the effects of malicious code. Pervasive configuration management and comprehensive software integrity controls may be effective in preventing execution of unauthorized code. In addition to commercial off-the-shelf software, malicious code may also be present in custom-built software. This could include logic bombs, back doors, and other types of cyber-attacks that could affect organizational missions/business functions.

Traditional malicious code protection mechanisms cannot always detect such code. In these situations, organizations rely instead on other safeguards including secure coding practices, configuration management and control, trusted procurement processes, and monitoring technologies to help ensure that software does not perform functions other than the functions intended.

Further Discussion

Malware changes on an hourly or daily basis, and it is important to update detection and protection mechanisms frequently to maintain the effectiveness of the protection.

Example

You have installed anti-malware software to protect a computer from malicious code. Knowing that malware evolves rapidly, you configure the software to automatically check for malware definition updates every day and update as needed [a].

Potential Assessment Considerations

Key References

Source References

Referenced Publications


1 NIST SP 800-171A, Assessing Security Requirements for Controlled Unclassified Information.

2 NIST SP 800-171 Revision 2, Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations.