NIST SP 800-53r5 — MA-04 Nonlocal Maintenance
source: false
type: canonical-control-reference
standard: NIST SP 800-53r5
assessment_standard: NIST SP 800-53Ar5
baseline_standard: NIST SP 800-53B
control_id: "MA-04"
family_id: "MA"
family: "Maintenance"
title: "Nonlocal Maintenance"
status: active
updated: 2026-09-10
authoritative_sources:
- "NIST SP 800-53r5 verified transcription"
- "NIST SP 800-53Ar5 verified transcription"
- "NIST SP 800-53B verified transcription"
baseline_membership:
low: true
moderate: true
high: true
privacy: false
related_controls:
- "AC-02"
- "AC-03"
- "AC-06"
- "AC-17"
- "AU-02"
- "AU-03"
- "IA-02"
- "IA-04"
- "IA-05"
- "IA-08"
- "MA-02"
- "MA-05"
- "PL-02"
- "SC-07"
- "SC-10"
MA-04 Nonlocal Maintenance
Canonical combined reference
Control text and discussion come from NIST SP 800-53r5; assessment procedures come from NIST SP 800-53Ar5; baseline membership comes from NIST SP 800-53B.
NIST SP 800-53r5 — Control
- a. Approve and monitor nonlocal maintenance and diagnostic activities;
- b. Allow the use of nonlocal maintenance and diagnostic tools only as consistent with organizational policy and documented in the security plan for the system;
- c. Employ strong authentication in the establishment of nonlocal maintenance and diagnostic sessions;
- d. Maintain records for nonlocal maintenance and diagnostic activities; and
- e. Terminate session and network connections when nonlocal maintenance is completed.
Discussion
Nonlocal maintenance and diagnostic activities are conducted by individuals who communicate through either an external or internal network. Local maintenance and diagnostic activities are carried out by individuals who are physically present at the system location and not communicating across a network connection. Authentication techniques used to establish nonlocal maintenance and diagnostic sessions reflect the network access requirements in NIST SP 800-53r5 IA-02. Strong authentication requires authenticators that are resistant to replay attacks and employ multi-factor authentication. Strong authenticators include PKI where certificates are stored on a token protected by a password, passphrase, or biometric. Enforcing requirements in NIST SP 800-53r5 MA-04 is accomplished, in part, by other controls. SP 800-63B6 provides additional guidance on strong authentication and authenticators.
Related Controls
Supporting Publications
- FIPS 140-31
- FIPS 1972
- FIPS 201-23
- SP 800-63-34
- SP 800-885
- SP 800-63B6
NIST SP 800-53Ar5 — Assessment Procedure
Assessment Objective
Determine if:
-
MA-04a.[01]— nonlocal maintenance and diagnostic activities are approved; -
MA-04a.[02]— nonlocal maintenance and diagnostic activities are monitored; -
MA-04b.[01]— the use of nonlocal maintenance and diagnostic tools are allowed only as consistent with organizational policy; -
MA-04b.[02]— the use of nonlocal maintenance and diagnostic tools are documented in the security plan for the system; -
MA-04c.— strong authentication is employed in the establishment of nonlocal maintenance and diagnostic sessions; -
MA-04d.— records for nonlocal maintenance and diagnostic activities are maintained; -
MA-04e.[01]— session connections are terminated when nonlocal maintenance is completed; -
MA-04e.[02]— network connections are terminated when nonlocal maintenance is completed.
Potential Assessment Methods and Objects
Examine
Select from:
- Maintenance policy.
- procedures addressing nonlocal system maintenance.
- remote access policy.
- remote access procedures.
- system design documentation.
- system configuration settings and associated documentation.
- maintenance records.
- records of remote access.
- diagnostic records.
- system security plan.
- other relevant documents or records.
Interview
Select from:
- Organizational personnel with system maintenance responsibilities.
- organizational personnel with information security responsibilities.
- system/network administrators.
Test
Select from:
- Organizational processes for managing nonlocal maintenance.
- mechanisms implementing, supporting, and/or managing nonlocal maintenance.
- mechanisms for strong authentication of nonlocal maintenance diagnostic sessions.
- mechanisms for terminating nonlocal maintenance sessions and network connections.
References
Source Assessment Procedure — NIST SP 800-53Ar5
NIST SP 800-53B — Baseline Membership
| Baseline | Membership |
|---|---|
| Low | Included |
| Moderate | Included |
| High | Included |
| Privacy | Not included |
Reference
Referenced Publications
6 Grassi PA, Fenton JL, Newton EM, Perlner RA, Regenscheid AR, Burr WE, Richer, JP, Lefkovitz NB, Danker JM, Choong Y-Y, Greene KK, Theofanos MF (2017) Digital Identity Guidelines: Authentication and Lifecycle Management. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-63B, Includes updates as of March 2, 2020. https://doi.org/10.6028/NIST.SP.800-63b
1 National Institute of Standards and Technology (2019) Security Requirements for Cryptographic Modules. (U.S. Department of Commerce, Washington, D.C.), Federal Information Processing Standards Publication (FIPS) 140-3. https://doi.org/10.6028/NIST.FIPS.140-3
2 National Institute of Standards and Technology (2001) Advanced Encryption Standard (AES). (U.S. Department of Commerce, Washington, D.C.), Federal Information Processing Standards Publication (FIPS) 197. https://doi.org/10.6028/NIST.FIPS.197
3 National Institute of Standards and Technology (2013) Personal Identity Verification (PIV) of Federal Employees and Contractors. (U.S. Department of Commerce, Washington, D.C.), Federal Information Processing Standards Publication (FIPS) 201-2. https://doi.org/10.6028/NIST.FIPS.201-2
4 Grassi PA, Garcia ME, Fenton JL (2017) Digital Identity Guidelines. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-63-3, Includes updates as of March 2, 2020. https://doi.org/10.6028/NIST.SP.800-63-3
5 Kissel RL, Regenscheid AR, Scholl MA, Stine KM (2014) Guidelines for Media Sanitization. (National Institute of Standards and Technology, Gaithersburg, MD), NIST Special Publication (SP) 800-88, Rev. 1. https://doi.org/10.6028/NIST.SP.800-88r1