Secure Controls Framework 2026.2 — PES-03.2 Lockable Physical Casings
source: false
type: canonical-control-reference
standard: Secure Controls Framework 2026.2
control_id: "PES-03.2"
domain_id: "PES"
domain: "Physical & Environmental Security"
title: "Lockable Physical Casings"
status: active
validation_cadence: "Annual"
relative_control_weighting: "5"
pptdf_applicability: "Facility"
nist_csf_function: "Protect"
updated: 2026-09-10
authoritative_sources:
- "SCF Overview & Practitioner Guidebook, version 2026.2"
source_sheet: "SCF 2026.2"
source_row: 1070
source_workbook_sha256: "9e0a4df4993726c95e636f04b3028d8b5edeba2bda45d16ed6722b13540e6835"
source_fidelity_audit: "2026-09-13"
PES-03.2 Lockable Physical Casings
Canonical SCF 2026.2 reference
Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.
Source and mapping limits
This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.
SCF 2026.2 — Control
Physical access control mechanisms exist to protect system components from unauthorized physical access (e.g., lockable physical casings).
Domain Principle
Physical & Environmental Security (PES): Protect physical environments through layered physical security and environmental controls that safeguard physical and digital assets from unauthorized access, theft, damage and disruption.
Organizations limit physical access to Technology Assets, Applications, Services and Data (TAASD) and monitor environmental conditions commensurate with risk to prevent unauthorized access and reduce equipment failure, damage or disruption from physical and environmental threats.
Control Question
Does the organization protect system components from unauthorized physical access (e.g., lockable physical casings)?
Operational Metadata
| Field | Value |
|---|---|
| Conformity validation cadence | Annual |
| Relative control weighting | 5 |
| PPTDF applicability | Facility |
| NIST CSF function grouping | Protect |
Possible Solutions & Considerations
Micro-Small Business
- Keep server room cool and document temperature requirements
Small Business
- Temperature and humidity monitoring for IT equipment rooms
Medium Business
- Environmental monitoring system for temperature and humidity
Large Business
- Enterprise environmental monitoring system (e.g., APC, Schneider Electric)
- Automated alerting
Enterprise
- Enterprise DCIM/environmental monitoring platform (e.g., Nlyte, Schneider EcoStruxure)
- Redundant sensors
- Automated HVAC controls
Assessment Objectives
PES-03.2_A01
system components to be protected from unauthorized physical access are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03(04)_ODP
Assessment rigor:
- 1
NIST SP 800-53A:
-
x
PES-03.2_A02
lockable physical casings are used to protect system components from unauthorized access.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03(04)
Assessment rigor:
- 1
NIST SP 800-53A:
-
x
Evidence Requests
- No evidence request is assigned in the source workbook.
Compensating Controls
Risk if Primary Control Is Not Implemented
Without Lockable Physical Casings, unauthorized physical access to facilities may enable theft, tampering, or direct attacks on infrastructure.
Possible Compensating Control 1
PES-05 — Monitoring Physical Access
Physical access control mechanisms exist to monitor for, detect and respond to physical security incidents.
Justification:
Monitoring Physical Access (PES-05) provides detective monitoring capability that compensates for the absence of Lockable Physical Casings (PES-03.2) by identifying unauthorized, anomalous, or non-compliant activity that the primary control would have prevented. Given the facility and physical environment focus of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Possible Compensating Control 2
PES-03 — Physical Access Control
Physical access control mechanisms exist to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).
Justification:
Physical Access Control (PES-03) provides access control enforcement that compensates for the absence of Lockable Physical Casings (PES-03.2) by restricting system and data access to authorized users through alternative identity and access mechanisms. Given the facility and physical environment focus of this control, this compensating control targets the same underlying risk objective through an alternative approach, helping to maintain an acceptable level of residual risk until the primary control can be implemented.
Applicability and Profile Membership
- SCRM Focus TIER 2 OPERATIONAL: Included
- SCRM Focus TIER 3 TACTICAL: Included
- SCR-CMM Level 0 Not Performed:
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
- SCR-CMM Level 1 Performed Informally:
Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include:
- Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation.
- Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices.
- Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs).
- IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.
- SCR-CMM Level 2 Planned & Tracked:
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity.
- Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners.
- IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD).
- Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards, procedures & guidelines).
- Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel.
- Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
- SCR-CMM Level 3 Well Defined:
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.
- Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners.
- A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities.
- Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation, proximity badge access, etc.).
- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).
- An implemented and operational physical security capability exists to protect system components from unauthorized physical access (e.g., lockable physical casings).
- SCR-CMM Level 4 Quantitatively Controlled:
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist:
- Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational.
- Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs).
- Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs).
- Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties.
- Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review).
- Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes.
- Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.
- SCR-CMM Level 5 Continuously Improving:
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:
- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.
- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.
- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
Framework Mappings
- American Institute of Certified Public Accountants (AICPA) Privacy Management Framework (PMF) (2020):
S7.2-POF5 - NIST SP 800 - 53 R4 - Security and Privacy Controls for Federal Information Systems and Organizations:
PE-3(4),SC-7(14) - NIST SP 800 - 53 R5 - Security and Privacy Controls for Information Systems and Organizations:
PE-03(04),SC-07(14) - NIST SP 800 - 53 R5 - Security and Privacy Controls for Information Systems and Organizations - Privacy Baseline:
SC-07(14) - NIST SP 800-82 Rev. 3 — Guide to Operational Technology (OT) Security:
PE-03(04),SC-07(14) - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations:
SC-7(14) - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations - Level 2 Baseline:
SC-7(14) - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations - Level 3 Baseline:
SC-7(14) - PCI DSS 4.0.1:
9.2.4 - PCI DSS 4.0.1:
9.2.4 - PCI DSS 4.0.1:
9.2.4 - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Low Baseline:
SC-07(14) - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Moderate Baseline:
SC-07(14) - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - High Baseline:
SC-07(14) - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Li - SAAS Baseline:
SC-07(14) - Saudi Arabia - SACS - 002 Third Party Cybersecurity Standard (2022):
VII.B.TPC-46 - New Zealand - Information Security Manual (ISM) v3.9:
8.2.5.C.01
Minimum Security Requirements
- No MCR or DSR designation is specified in the source workbook.
Risk and Threat Mappings
Risks
-
R-AC-1 -
R-AC-4 -
R-AM-1 -
R-AM-2 -
R-BC-1 -
R-BC-2 -
R-BC-3 -
R-BC-4 -
R-BC-5 -
R-EX-1 -
R-EX-2 -
R-EX-3 -
R-EX-4 -
R-EX-5 -
R-EX-7 -
R-GV-1 -
R-GV-2 -
R-GV-3 -
R-GV-4 -
R-GV-5 -
R-GV-6 -
R-GV-7 -
R-IR-1 -
R-IR-4 -
R-SA-1 -
R-SC-1 -
R-SC-2 -
R-SC-3 -
R-SC-4 -
R-SC-5 -
R-SC-6
Threats
-
NT-7 -
MT-1 -
MT-2 -
MT-7 -
MT-8 -
MT-9 -
MT-10 -
MT-11 -
MT-12 -
MT-13 -
MT-14 -
MT-15 -
MT-24 -
MT-25 -
MT-27 -
MT-28