Secure Controls Framework 2026.2 — PES-03 Physical Access Control
source: false
type: canonical-control-reference
standard: Secure Controls Framework 2026.2
control_id: "PES-03"
domain_id: "PES"
domain: "Physical & Environmental Security"
title: "Physical Access Control"
status: active
validation_cadence: "Annual"
relative_control_weighting: "10"
pptdf_applicability: "Facility"
nist_csf_function: "Protect"
updated: 2026-09-10
authoritative_sources:
- "SCF Overview & Practitioner Guidebook, version 2026.2"
source_sheet: "SCF 2026.2"
source_row: 1068
source_workbook_sha256: "9e0a4df4993726c95e636f04b3028d8b5edeba2bda45d16ed6722b13540e6835"
source_fidelity_audit: "2026-09-13"
PES-03 Physical Access Control
Canonical SCF 2026.2 reference
Control content, assessment objectives, evidence requests, compensating controls, and mappings come from the official SCF 2026.2 workbook.
Source and mapping limits
This card preserves the retained SCF 2026.2 workbook. Framework mappings are SCF cross-references, not proof of equivalence or compliance. Suggested solutions, maturity descriptions, and possible compensating controls require applicability review; they are not additional mandatory control requirements.
SCF 2026.2 — Control
Physical access control mechanisms exist to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).
Domain Principle
Physical & Environmental Security (PES): Protect physical environments through layered physical security and environmental controls that safeguard physical and digital assets from unauthorized access, theft, damage and disruption.
Organizations limit physical access to Technology Assets, Applications, Services and Data (TAASD) and monitor environmental conditions commensurate with risk to prevent unauthorized access and reduce equipment failure, damage or disruption from physical and environmental threats.
Control Question
Does the organization enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible)?
Operational Metadata
| Field | Value |
|---|---|
| Conformity validation cadence | Annual |
| Relative control weighting | 10 |
| PPTDF applicability | Facility |
| NIST CSF function grouping | Protect |
Possible Solutions & Considerations
Micro-Small Business
- Physical security policy
- Door locks and key management
Small Business
- Physical security policy
- Access log
- Visitor procedures
Medium Business
- Staffed lobby (receptionist)
- Physical security guards
- Verify individual access authorizations before granting access to the facility.
- Control entry to the facility containing the system using physical access devices and/or guards.
- Control access to areas officially designated as publicly accessible in accordance with the organization's assessment of risk.
- Secure keys, combinations and other physical access devices.
Large Business
- Staffed lobby (receptionist)
- Physical security guards
- Verify individual access authorizations before granting access to the facility.
- Control entry to the facility containing the system using physical access devices and/or guards.
- Control access to areas officially designated as publicly accessible in accordance with the organization's assessment of risk.
- Secure keys, combinations and other physical access devices.
Enterprise
- Staffed lobby (receptionist)
- Physical security guards
- Verify individual access authorizations before granting access to the facility.
- Control entry to the facility containing the system using physical access devices and/or guards.
- Control access to areas officially designated as publicly accessible in accordance with the organization's assessment of risk.
- Secure keys, combinations and other physical access devices.
Assessment Objectives
PES-03_A01
physical access controls to control access to areas within the facility designated as publicly accessible are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[05]
Assessment rigor:
- 1
NIST SP 800-53A:
-
x
PES-03_A02
physical access authorizations are enforced at entry and exit points to the facility where the system resides by controlling ingress and egress with physical access control systems, devices, or guards.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03a.01 -
171A_R3_A.03.10.07.a.02
Assessment rigor:
- 1
NIST SP 800-53A:
-
x
NIST SP 800-171Ar3:
-
x
PES-03_A03
entry and exit points to the facility in which the system resides are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[01]
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A04
entry or exit points for which physical access logs are maintained are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[04]
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A05
physical access devices are identified.
PPTDF applicability:
- Process
Origin(s):
-
171A_3.10.5[a] -
53A_R5_PE-03_ODP[02] -
53A_R5_PE-03_ODP[03]
Assessment rigor:
- 1
CMMC Level 1 AOs:
-
PE.L1-B.1.IX[d]
NIST SP 800-53A:
-
x
NIST SP 800-171A:
-
x
PES-03_A06
physical access devices are controlled.
PPTDF applicability:
- Facility
Origin(s):
-
171A_3.10.5[b]
Assessment rigor:
- 1
CMMC Level 1 AOs:
-
PE.L1-B.1.IX[e]
NIST SP 800-171A:
-
x
PES-03_A07
physical access devices are managed.
PPTDF applicability:
- Facility
Origin(s):
-
171A_3.10.5[c]
Assessment rigor:
- 1
CMMC Level 1 AOs:
-
PE.L1-B.1.IX[f]
NIST SP 800-171A:
-
x
PES-03_A08
circumstances requiring visitor escorts and control of visitor activity are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[06]
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A09
physical access devices to be inventoried are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[07]
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A10
frequency at which to inventory physical access devices is defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[08]
Assessment rigor:
- 3
SCF-defined parameters:
-
at least annually or earlier as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A11
frequency at which to change combinations is defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[09]
Assessment rigor:
- 3
SCF-defined parameters:
-
as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A12
frequency at which to change keys is defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03_ODP[10]
Assessment rigor:
- 3
SCF-defined parameters:
-
as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A13
physical access authorizations are enforced at entry and exit points by controlling ingress and egress to the facility.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03a.02
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A14
physical access event logs are maintained for entry or exit points.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03b.
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A15
access to areas within the facility designated as publicly accessible are maintained by implementing physical access controls.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03c.
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A16
visitors are escorted.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03d.[01]
Assessment rigor:
- 1
CMMC Level 1 AOs:
-
PE.L1-B.1.IX[a]
NIST SP 800-53A:
-
x
PES-03_A17
visitor activity is controlled circumstances.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03d.[02]
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A18
physical access devices are inventoried frequently.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03f.
Assessment rigor:
- 3
SCF-defined parameters:
-
at least annually or earlier as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A19
combinations are changed frequently, when combinations are compromised or when individuals possessing the combinations are transferred or terminated.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03g.[01]
Assessment rigor:
- 3
SCF-defined parameters:
-
as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A20
keys are changed frequency, when keys are lost or when individuals possessing the keys are transferred or terminated.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03g.[02]
Assessment rigor:
- 3
SCF-defined parameters:
-
as required by a security relevant event
NIST SP 800-53A:
-
x
PES-03_A21
the frequency at which to perform security checks at the physical perimeter of the facility or system for exfiltration of information or removal of system components is defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03(02)_ODP
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A22
security checks are performed C at the physical perimeter of the facility or system for exfiltration of information or removal of system components.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03(02)
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A23
physical access points to the facility where the system resides are defined.
PPTDF applicability:
- Process
Origin(s):
-
53A_R5_PE-03(03)_ODP
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A24
guards are employed to control physical access points to the facility where the system resides 24 hours per day, 7 days per week.
PPTDF applicability:
- Facility
Origin(s):
-
53A_R5_PE-03(03)
Assessment rigor:
- 3
NIST SP 800-53A:
-
x
PES-03_A25
physical access restrictions associated with changes to the system are enforced.
PPTDF applicability:
- Process
Origin(s):
-
171A_R3_A.03.04.05[03]
Assessment rigor:
- 2
NIST SP 800-171Ar3:
-
x
PES-03_A26
keys, combinations, and other physical access devices are secured.
PPTDF applicability:
- Facility
Origin(s):
-
171A_R3_A.03.10.07.d -
53A_R5_PE-03e.[01] -
53A_R5_PE-03e.[02] -
53A_R5_PE-03e.[03]
Assessment rigor:
- 2
NIST SP 800-53A:
-
x
NIST SP 800-171Ar3:
-
x
Evidence Requests
-
E-PES-05— Physical Security Operations (Physical Security): Documented evidence of the organization's physical security capabilities as it pertains to operating and monitoring Physical Access Control (PAC) mechanisms. -
E-PES-06— Physical Access Control Logs (Physical Security): Documented evidence of physical access control logs or records. -
E-PES-07— Physical Access Control Devices (Physical Security): Documented evidence of Physical Access Control (PAC) mechanisms. -
E-PES-08— Physical Access Control Device Inventories (Physical Security): Documented evidence of inventory records of physical access control devices. -
E-PES-09— Key & Combination Changes (Physical Security): Documented evidence of key and lock combination changes.
Compensating Controls
Risk if Primary Control Is Not Implemented
Not Applicable (N/A) - Not eligible for a compensating control, due to being a material control (control weighting of 10/10). A deficiency with or absence of a material control would be a material weakness to the organization's Security, Compliance & Resilience Program (SCRP).
Possible Compensating Control 1
N/A — N/A
N/A
Justification:
N/A
Possible Compensating Control 2
N/A — N/A
N/A
Justification:
N/A
Applicability and Profile Membership
- SCRM Focus TIER 2 OPERATIONAL: Included
- SCRM Focus TIER 3 TACTICAL: Included
- SCR-CMM Level 0 Not Performed:
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
- SCR-CMM Level 1 Performed Informally:
SCR-CMM Level 1 criteria definitions are not available for this control:
- A reasonable person would conclude this control requires a structured process.
- At this level of maturity, the "ad hoc" nature of performing a capability informally would indicate the intent of the control is not met due to a lack of consistency and formality.
- SCR-CMM Level 2 Planned & Tracked:
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity.
- Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners.
- IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD).
- Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards, procedures & guidelines).
- Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel.
- Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
- Physical security controls and technologies ensure that only authorized personnel are allowed access to secure areas.
- A facilities maintenance team, or similar function, manages the operation of automated physical and environmental protection controls.
- Physical security controls and technologies are configured to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).
- SCR-CMM Level 3 Well Defined:
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:
- Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function.
- Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners.
- A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities.
- Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation, proximity badge access, etc.).
- The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls).
- An implemented and operational physical security capability exists to enforce physical access authorizations for all physical access points (including designated entry/exit points) to facilities (excluding those areas within the facility officially designated as publicly accessible).
- SCR-CMM Level 4 Quantitatively Controlled:
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist:
- Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational.
- Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs).
- Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs).
- Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties.
- Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review).
- Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes.
- Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.
- SCR-CMM Level 5 Continuously Improving:
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:
- There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control.
- Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies.
- While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
- SCF SCRMS: PES-03
- SCF CORE ESP Level 1 Foundational: PES-03
- SCF CORE ESP Level 2 Critical Infrastructure: PES-03
- SCF CORE ESP Level 3 Advanced Threats: PES-03
- SCF CORE Fundamentals: PES-03
- SCF CORE Mergers, Acquisitions & Divestitures (MA&D): PES-03
Framework Mappings
- American Institute of Certified Public Accountants (AICPA) Privacy Management Framework (PMF) (2020):
S7.2,S7.2-POF4,S7.2-POF5 - AICPA Trust Services Criteria (2017; revised Points of Focus 2022):
CC6.4,CC6.4-POF1,CC6.4-POF2 - Control Objectives for Information and Related Technologies (COBIT) (2019):
DSS05.05 - Cloud Security Alliance (CSA) Cloud Controls Matrix (CCM) v4.1.0:
DCS-08 - Cloud Security Alliance (CSA) Internet of Things Security Controls Framework v2:
PHY-01 - Government Risk and Authorization Management Program (GovRAMP):
PE-03 - Government Risk and Authorization Management Program (GovRAMP) - Low:
PE-03 - Government Risk and Authorization Management Program (GovRAMP) - Low+:
PE-03 - Government Risk and Authorization Management Program (GovRAMP) - Moderate:
PE-03 - Government Risk and Authorization Management Program (GovRAMP) - High:
PE-03 - ISO/IEC 27002:2022 - Information security, cybersecurity and privacy protection - Information security controls:
5.15,5.18,7.1,7.4 - ISO/IEC 27017:2015 - Information technology - Security techniques - Code of practice for information security controls based on ISO/IEC 27002 for cloud services:
9.1.1,11.1.1 - ISO/IEC 27018:2025 - Information security, cybersecurity and privacy protection - Guidelines for protection of personally identifiable information (PII) in public clouds acting as PII processors:
5.15,5.18,7.1,7.4 - Motion Picture Association (MPA) Content Security Best Practices Common Guidelines v5.3.1:
OP-1.0,PS-1.0,PS-1.2 - NIST Privacy Framework v1.0:
PR.AC-P2 - NIST SP 800 - 53 R4 - Security and Privacy Controls for Federal Information Systems and Organizations:
PE-3,PE-3(2),PE-3(3) - NIST SP 800 - 53 R5 - Security and Privacy Controls for Information Systems and Organizations:
PE-03,PE-03(02),PE-03(03) - NIST SP 800 - 53 R5 - Security and Privacy Controls for Information Systems and Organizations - Low Baseline:
PE-03 - NIST SP 800 - 66 R2 - Implementing the Health Insurance Portability and Accountability Act (HIPAA) Security Rule: A Cybersecurity Resource Guide:
164.310(a),164.310(c) - NIST SP 800-82 Rev. 3 — Guide to Operational Technology (OT) Security:
PE-03,PE-03(02),PE-03(03) - NIST SP 800-82 Rev. 3 — Low Ot Overlay:
PE-03 - NIST SP 800-82 Rev. 3 — Moderate Ot Overlay:
PE-03 - NIST SP 800-82 Rev. 3 — High Ot Overlay:
PE-03 - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations:
PE-3,PE-3(2) - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations - C - SCRM Baseline:
PE-3 - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations - Level 2 Baseline:
PE-3,PE-3(2) - NIST SP 800 - 161 R1 UDP1 - Cybersecurity Supply Chain Risk Management Practices for Systems and Organizations - Level 3 Baseline:
PE-3,PE-3(2) - NIST SP 800 - 171 R2 - Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations:
3.10.3,3.10.5 - NIST SP 800 - 171 R3 - Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations:
03.04.05,03.10.02.a,03.10.07.a,03.10.07.a.01,03.10.07.a.02,03.10.07.d - NIST SP 800 - 171A - Assessing Security Requirements for Controlled Unclassified Information:
3.10.5[a],3.10.5[b],3.10.5[c] - NIST SP 800 - 171A R3 - Assessing Security Requirements for Controlled Unclassified Information:
A.03.04.05[03],A.03.10.02.a[01],A.03.10.07.a.01,A.03.10.07.a.02,A.03.10.07.d - NIST Cybersecurity Framework v2.0:
PR.AA, PR.AA-06, DE.CM-02 - PCI DSS 4.0.1:
9.1,9.1.2,9.2,9.2.1 - PCI DSS 4.0.1:
9.2.1 - PCI DSS 4.0.1:
9.2.1 - PCI DSS 4.0.1:
9.2.1 - PCI DSS 4.0.1:
9.1.2,9.2.1 - PCI DSS 4.0.1:
9.1.2,9.2.1 - Society for Worldwide Interbank Financial Telecommunication Customer Security Controls Framework 2025:
3.1 - Trusted Information Security Assessment Exchange (TISAX) 6.0.3:
8.1.3 - US - Department of Justice - Criminal Justice Information Services (CJIS) Security Policy v6.0:
PE-3 - US - Department of Energy (DOE) - Cybersecurity Capability Maturity Model version 2.1:
ACCESS-3a,ACCESS-3d,ACCESS-3e,ACCESS-3f,ACCESS-3g,ACCESS-3j - US - Department of War (DoW) - Cybersecurity Maturity Model Certification (CMMC) v2.0 - Level 1:
PE.L1-B.1.IX - US - Department of War (DoW) - Cybersecurity Maturity Model Certification (CMMC) v2.0 - Level 1 Assessment Objectives:
PE.L1-B.1.IX[a],PE.L1-B.1.IX[d],PE.L1-B.1.IX[e],PE.L1-B.1.IX[f] - US Department of War (DoW) - Cybersecurity Maturity Model Certification (CMMC) v2.0 - Level 2:
PEL2.-3.10.3,PEL2.-3.10.5 - US Department of War (DoW) - Cybersecurity Maturity Model Certification (CMMC) v2.0 - Level 3:
AC.L3-3.1.2E - US - Federal Acquisition Regulation (FAR) 52.204 - 21 - Basic Safeguarding of Covered Contractor Information Systems:
52.204-21(b)(1)(ix) - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Low Baseline:
PE-03 - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Moderate Baseline:
PE-03 - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - High Baseline:
PE-03 - US - Federal Risk and Authorization Management Program (FedRAMP) R5 - Li - SAAS Baseline:
PE-03 - US - 33 CFR Part 101 Subpart F (up to date as of 4 - 17 - 2026):
101.650(i)(1) - US - Health Insurance Portability and Accountability Act (HIPAA) Administrative Simplification (2013):
§ 164.310(a)(2)(ii),§ 164.310(a)(2)(iii),§ 164.310(c) - US - Health Insurance Portability and Accountability Act (HIPAA) Security Rule (2013):
§ 164.310(a)(2)(ii),§ 164.310(a)(2)(iii),§ 164.310(c) - US - Internal Revenue Service (IRS) 1075 (2021):
2.B.3.4,PE-3,PE-3(CE-2) - US - Centers for Medicare & Medicaid Services MARS - E Document Suite, Version 2.0:
PE-3,PE-3.a,PE-3.b,PE-3.c,PE-3.d,PE-3.e,PE-3.f,PE-3.g,PE-3.h,PE-3.i,PE-3-IS.1,PE-3-IS.4 - US - North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) (2024):
CIP-006-6 1.1,CIP-006-6 1.3,CIP-006-6 1.5,CIP-006-6 1.10 - US - National Industrial Security Program Operating Manual (NISPOM) (2020):
§117.15(e)(4) - US - California Consumer Privacy Act (CCPA) (January 2026) - amended California Privacy Rights Act (CPRA):
7123(c)(3)(D) - US - Massachusetts 201 CMR 17.00 (2008):
17.03(2)(g) - US - Texas DIR Security Control Standards Catalog v2.2:
PE-03 - US - Texas Risk & Authorization Management Program 2.0 - Level 1:
PE-03 - US - Texas Risk & Authorization Management Program 2.0 - Level 2:
PE-03 - US - Vermont Data Broker Registration Act (Act 171 of 2018):
2447(b)(7) - EU - European Union Agency for Cybersecurity NIS2 Annex (2024):
13.1.2(c),13.3.1,13.3.2(b) - Germany - Cloud Computing Compliance Controls Catalogue (C5) (2020):
PS-02-DOAR - Saudi Arabia - Operational Technology Cybersecurity Controls (OTCC - 1: 2022):
2-13-1-3 - Saudi Arabia - SACS - 002 Third Party Cybersecurity Standard (2022):
VII.B.TPC-82 - Saudi Arabia - Saudi Arabian Monetary Authority (SAMA) Cyber Security Framework Version 1.0 (2017):
3.3.2.3.a - Spain - ICT Security Guide CCN - STIC 825 (2026):
op.acc.2,op.acc.4,op.acc.5,mp.if.1 - UAE - National Information Assurance Framework (NIAF) (2023):
3.2.2 - UK - Ministry of Defence Standard (DEFSTAN) 05 - 138 (2024):
1500 - UK - Ministry of Defence Standard (DEFSTAN) 05 - 138 (2024) - L1:
1500 - UK - Ministry of Defence Standard (DEFSTAN) 05 - 138 (2024) - L2:
1500 - UK - Ministry of Defence Standard (DEFSTAN) 05 - 138 (2024) - L3:
1500 - Australia - Information Security Manual (ISM) (March 2026):
ISM-1296 - India - SEBI Cybersecurity and Cyber Resilience Framework (2024):
PR.AA.S10 - Japan - Information System Security Management and Assessment Program (ISMAP):
11.1.1,11.1.1.1,11.1.1.2,11.1.1.3,11.1.1.4,11.1.1.5,11.1.1.6,11.1.1.7,11.1.2,11.1.2.1,11.1.2.2,11.1.2.5,11.1.2.10 - New Zealand - HISF MicroSmall (2023):
HHSP48,HML48 - New Zealand - HISO 10029:2024 NZ Health Information Security Framework Guidance for Suppliers:
HSUP40 - Singapore - Monitory Authority of Singapore (MAS) Technology Risk Management (TRM) Guidelines (2021):
8.5.6(e) - Argentina - Protection of Personal Data (2018):
B.2.4-1,B.2.4-2 - Canada - OSFI B - 13 (2022):
3.2.10 - Canada - Protecting controlled information in non - Government of Canada systems and organizations (ITSP.10.171) (2025):
03.04.05,03.10.02.A,03.10.07.A,03.10.07.A.01,03.10.07.A.02,03.10.07.D
Minimum Security Requirements
- No MCR or DSR designation is specified in the source workbook.
Risk and Threat Mappings
Risks
-
R-AC-1 -
R-AC-2 -
R-AC-3 -
R-AC-4 -
R-AM-1 -
R-AM-2 -
R-AM-3 -
R-BC-1 -
R-BC-2 -
R-BC-3 -
R-BC-4 -
R-BC-5 -
R-EX-1 -
R-EX-2 -
R-EX-3 -
R-EX-4 -
R-EX-5 -
R-EX-7 -
R-GV-1 -
R-GV-2 -
R-GV-3 -
R-GV-4 -
R-GV-5 -
R-GV-6 -
R-GV-7 -
R-GV-8 -
R-IR-1 -
R-IR-2 -
R-IR-4 -
R-SA-1 -
R-SC-1 -
R-SC-2 -
R-SC-3 -
R-SC-4 -
R-SC-5 -
R-SC-6
Threats
-
NT-2 -
NT-3 -
NT-4 -
NT-5 -
NT-6 -
NT-7 -
NT-8 -
NT-9 -
NT-10 -
NT-11 -
NT-12 -
NT-13 -
NT-14 -
MT-1 -
MT-2 -
MT-3 -
MT-4 -
MT-5 -
MT-6 -
MT-7 -
MT-8 -
MT-9 -
MT-10 -
MT-11 -
MT-12 -
MT-13 -
MT-14 -
MT-15 -
MT-24 -
MT-25 -
MT-27 -
MT-28