Open in TheBrain

NIST RMF SP 800-37r2 — TASK M-4 Authorization Package Updates


source: false

type: canonical-control-reference

standard: "NIST SP 800-37 Rev. 2 RMF"

document_version: "2"

criterion_id: "TASK M-4"

family_id: "M"

family: "M Monitor"

title: "Authorization Package Updates"

status: active

assessment_criterion: true

reference_basis: "complete published NIST task block; supplemental SCF mappings"

normative_text_included: true

updated: 2026-09-13

scf_mappings:

- "IAO-07"

source_pdf_pages: [98, 99]

authoritative_sources:

- "NIST SP 800-37 Rev. 2, December 2018"

- "SCF STRM NIST SP 800-37r2"


TASK M-4 Authorization Package Updates

Public-source assessment reference

This card contains the complete task block from NIST SP 800-37 Rev. 2 (December 2018): task, inputs, outputs, responsibilities, discussion, and published references. SCF relationships are supplemental mappings, not the source of RMF task text.

Criterion Text

Update plans, assessment reports, and plans of action and milestones based on the results of the continuous monitoring process.

Potential Inputs

Security and privacy assessment reports; organization- and system-level risk assessment results; security and privacy plans; plans of action and milestones.

Expected Outputs

Updated security and privacy assessment reports;1 updated plans of action and milestones; updated risk assessment results; updated security and privacy plans.

Primary Responsibility

System Owner; Common Control Provider.

Supporting Roles

Information Owner or Steward; System Security Officer; System Privacy Officer; Senior Agency Official for Privacy; Senior Agency Information Security Officer.

System Development Life Cycle Phase

Discussion

To achieve near real-time risk management, the organization updates security and privacy plans, security and privacy assessment reports, and plans of action and milestones on an ongoing basis. Updates to the plans reflect modifications to controls based on risk mitigation activities carried out by system owners or common control providers. Updates to control assessment reports reflect additional assessment activities carried out to determine control effectiveness based on implementation details in the plans. Plans of action and milestones are updated based on progress made on the current outstanding items; address security and privacy risks discovered as part of control effectiveness monitoring; and describe how the system owner or common control provider intends to address those risks. The updated information raises awareness of the security and privacy posture of the system and the common controls inherited by the system, thereby, supporting near real-time risk management and the ongoing authorization process.

The frequency of updates to risk management information is at the discretion of the system owner, common control provider, and authorizing officials in accordance with federal and organizational policies and is consistent with the organizational and system-level continuous monitoring strategies. The updates to information regarding the security and privacy posture of the system and the common controls inherited by the system are accurate and timely since the information provided influences ongoing actions and decisions by authorizing officials and other senior leaders within the organization. The use of automated support tools and organization-wide security and privacy program management practices ensure that authorizing officials can readily access the current security and privacy posture of the system. Ready access to the current security and privacy posture supports continuous monitoring and ongoing authorization and promotes the near real-time management of risk to organizational operations and assets, individuals, other organizations, and the Nation.

Organizations ensure that information needed for oversight, management, and auditing purposes is not modified or destroyed when updating security and privacy plans, assessment reports, and plans of action and milestones. Providing an effective method to track changes to systems through configuration management procedures is necessary to achieve transparency and traceability in the security and privacy activities of the organization; to obtain individual accountability for any security or privacy actions; and to understand emerging trends in the security and privacy programs of the organization.

Task References

SP 800-302; SP 800-53A3.

SCF Relationships

Notes

References

Referenced Publications and Source Notes


1 If a comparable report meets the requirements of what is to be included in an assessment report (e.g., a report generated from a security or privacy management and reporting tool), then the comparable report would constitute the assessment report. (NIST source footnote 108.)

2 National Institute of Standards and Technology Special Publication 800-30, Revision 1, Guide for Conducting Risk Assessments, September 2012. https://doi.org/10.6028/NIST.SP.800-30r1 (NIST source reference SP 800-30.)

3 National Institute of Standards and Technology Special Publication 800-53A, Revision 4, Assessing Security and Privacy Controls in Federal Information Systems and Organizations: Building Effective Security Assessment Plans, July 2008. https://doi.org/10.6028/NIST.SP.800-53Ar4 (NIST source reference SP 800-53A.)